6.9 As required

6.9.1 Check, clean the air filter, replace if necessary

Fig. 81
Fig. 82
70
NOTICE!
Contamination of the air filter depends mainly on the
proportion of dust in the intake air, if necessary clean
several times a day.
Do not use gasoline or hot fluids to clean the air filter.
In case of wet or sticky contamination replace the air
filter.
The air filter must be changed after several times
cleaning, but at the latest after one year.
Do not continue to use a damaged air filter. If in doubt
use a new air filter.
Do not run the engine without air filter.
Remove cover (1) Ä Fig. 81, carefully take out air filter (2).
NOTICE!
Make sure that no dirt falls into the air intake channel.
WARNING!
Danger of injury!
Always wear protective clothes (goggles, gloves) when
working with compressed air.
In case of dry fine dust blow out the air filter carefully from
inside to outside with dry, clean compressed air Ä Fig. 82
(max. 6 bar (87 psi)).
NOTICE!
Before installation check seals and air filter for
damage, replace if necessary.
Insert the air filter (2) Ä Fig. 81 and close the air filter cover
(1).