Fig. 70
Fig. 71
6.8.5 Replacing the starter rope
Fig. 72
Remove the protection grid on the left hand side of the
engine Ä Fig. 70.
Adjust the idle speed using the rear stop screw (2) on the
engine speed control lever (1) Ä Fig. 71.
Adjust the maximum speed by the front stop screw (3).
Secure the stop screws (2, 3).
Reassemble the protection grid on the left hand side of the
engine Ä Fig. 70. Retighten the fastening screws with a
tightening torque of 25 Nm (18 ft.lbs).
Adjust the throttle cable, if this should be necessary.
NOTICE!
Do not mix up the fastening screws for the recoil
starter by mistake!
Unscrew the fastening screws (1), (4) and (6) Ä Fig. 72 and
take off the recoil starter.