Menu 14 – Tools
Menu No.
14.1
14.2
14.3
14.4
14.5
14.6
Solar Gate Mode : Optimises the Control Card for Solar Applications
14.7
Optimises the Control Card for the correct Blade Fuse used
14.8
14.9
14.10
14.1 Battery Type
The MCS can be used with 2 types of backup batteries, Lead Acid & Lithium-ion.
Lead Acid. Never connect a lithium battery when lead acid mode is selected. Always
select the correct battery type.
14.2 Set the Supply Voltage
The control card automatically sets the supply voltage during setup. This option allows you to manually
set the control card to 12 or 24 Volt supply. To use the control card in a solar application you must set
the correct voltage in the Tools. This will disable the automatic voltage sensing which could causes
problems in solar applications.
14.3 Resets Controller
Reset all settings to factory default. Also removes password.
14.4 Test Inputs
This allows you to test all the external devices connected to the controllers inputs. UPPERCASE means
input is activated and lowercase means input is activated.
14.5 Travel Timer for Slip Clutch Motors
This allows you to use the controller with travel time. Used for Slip clutch or Hydraulic Motors
14.8 Slow Speed Ramp Down Time
This allows you to change the time it takes the gate to change its speed from fast to slow.
14.9 Magnetic Limit Switch
Only enable this option when using Elsema's magnetic Limit Switch.
www.elsema.com
Tools
Battery Type : Lithium-ion or Lead Acid battery
Set the Supply Voltage : 12 or 24 Volts
Resets Controller to Factory Settings
Test Inputs
Travel Timer for Slip Clutch Motors
Fuse Type : 10 or 15 Amps
Slow Speed Ramp Down Time
Magnetic Limit Switch
Exit
Only use Lithium-ion batteries supplied by Elsema.
Default setting is
27
Need help?
Do you have a question about the Eclipse MCS and is the answer not in the manual?