1
Command Summary
The tables in this section summarize the PROFINET Controller Command Line Interface commands.
In addition, they indicate the access levels and modes where various commands are valid.
A command that can set a parameter and that has an equivalent show command to display the
current value(s) associated with that parameter displays the same information as the show
command form if the command is entered without any parameters. For example, entering
deviceName in Configuration mode with no parameters displays the same information as show
config deviceName.
Commands/parameter names that can be unambiguously interpreted with fewer letters are accepted
as though the full command/parameter were entered. For example, the command show config ip
displays the same information as show config i because there are no other parameters following
show config that begin with i. Likewise, the whole command can be abbreviated sho co i.
Commands and parameters (when applicable) are not case-sensitive.
In the tables that follow:
Global
Non-Global
[ ]
< >
Commonly-Performed Tasks
To do this:
Clear the screen
Display configuration of Device Name, IP parameters and
redundant media role
Display detailed port information.
Display details on the most recent software exceptions.
Display help for the current access level
Display or change shell terminal configuration
Display parameters for a command
Display saved fatal error debug data stored non-volatile
memory.
Display summary of internal and external port information.
Display the local log table
End the Command Line Interface Session.
Go to the Modify access level (Monitor mode)
Go to the Monitor access level (Modify mode)
Restart the module firmware. (Modify mode)
Send ICMP Echo requests. (Modify mode)
Start the module identification LED blink pattern (Modify mode)
Stop the module identification LED blink pattern (Modify mode)
PACSystems* RX3i PROFINET Controller Command Line Interface Manual – July 2011
1-6
The command is available in all modes and access levels.
The command capability or access to certain parameters change in some modes
or access levels.
The parameter is optional. Within the brackets each possible option for that
parameter is listed, with a bar | between parameters.
Parameters that can take on a range of values are shown in angle brackets
Use this command:
cls
show config or show config all
show port all
show debug exception
help
shConfig
<command> ?
show debug fatalInfo
show port
log
terminate
login
Logout
restart
ping
blinkId begin
blinkId end
GFK-2572

Hide quick links:

Advertisement

Table of Contents
loading