System Description
Self-Configured Banded or Non-LFE Broadband Millimeter-Wave Network Analyzer
System
Self-Configured Banded or Non-LFE Broadband Millimeter-Wave
Network Analyzer System
Non-LFE broadband millimeter-wave capability is only available with the
N5293/5A millimeter-wave modules and operates from 10 MHz to
110/120 GHz. For banded systems, the frequency range will vary from
60 GHz to 1.5 THz depending on the OML/VDI millimeter-wave heads
used in the system.
IMPORTANT! Only PNAs and PNA-X network analyzers with a frequency
range equal to greater than 20 GHz are compatible with the N5292A test
set controller.
IMPORTANT! For additional information on the OML/VDL heads, refer to
"OML/VDI and N5293A/5A Test Heads – Banded Configuration Calibration
(Only)" on page

Introduction

This section of this document describes system installation and operation for a
banded or non-LFE broadband millimeter-wave system using an N5292A
Millimeter Head Controller. Banded and non-LFE broadband millimeter-wave
systems are made up of three types of major components: a PNA or PNA-X, a
N5292A controller test set, and millimeter-wave heads. These components are
generally purchased separately and assembled by the customer into a system
at the customer's site. This section of the document focuses on receiving the
controller with accessories and then on system installation and operation.
IMPORTANT! For banded systems that are using the OML modules that
require DC bias, a separate N5260AK91 power supply and adapter is
required. See also,
require DC bias, use the VDI-175 power supply.
Each OML/VDI module requires a N5290A304 cable adapter to connect to
the N5292A test set. See also
For additional information on the OML/VDL heads, refer to
N5293A/5A Test Heads – Banded Configuration Calibration (Only)" on
page
Table 2-3
options.
millimeter-wave modules. Typical system configurations are pictured in
2-1 on page
page
Keysight Self-Configured System Installation Guide
3-21.
Table 2-9 on page
3-21.
and
Table 2-4
list compatible PNA and PNA-X models with required
Figure 2-10 on page 22
5,
Figure 2-2 on page
7.
2-19. And, for VDI modules that
Table 2-9 on page
2-19.
and
Figure 2-11 on page 23
5,
Figure 2-3 on page
"OML/VDI and
list available
Figure
6, and
Figure 2-4 on
2-3