Program Backup and Restore Operations
Key Sequence
3.
Specify the start address for the data that is to be restored or compared.
4.
Start playing the cassette tape.
5.
Within 5 seconds, press SHIFT and PLAY/SET to restore data or VER to
compare data.
Program restoration or comparison continues until END(01) is reached or
until the tape is finished, at which time the program size in Kwords is dis-
played. At that time the program size in Kwords is displayed. Even if END(01)
is reached before the end of the tape, the restoring or comparison operation
will continue through the end of the tape unless CLR is pressed to cancel.
To restore or compare program data recorded on two sides of a tape or on
two or more tapes, begin restoring or comparing from the lowest address.