1PH7 AC Main Spindle Motors
1.7 Mounting 1PH4/7 motors
1.7
Mounting instruc-
tions
1PH7
Cable outlet, NDE
1PH7/1-18
Mounting 1PH4/7 motors
Warning
!
Electric motors have parts and components which are at hazardous voltage levels.
If motors are not correctly handled, this can result in death, severe bodily injury as
well as significant material damage. Therefore, please observe all of the warning
information in this Chapter and on the product itself.
S
Only appropriately qualified personnel may service/maintain the motor.
S
The motor must be isolated from the line supply and grounded before star-
ting any work on the motor.
S
Only spare parts certified by the manufacturer may be used.
S
The specified maintenance intervals and measures as well as the repair
and replacement procedures which are specified, must be observed.
Warning
!
S
All of the hoisting lugs must be used when transporting the motors!
S
Any work carried–out must be made with the plant/system in a no–voltage
condition (powered–down)!
S
The motor must be connected–up according to the circuit diagrams sup-
plied.
S
In the terminal box, it should be ensured that the connecting cables are
insulated with respect to the terminal panel cover.
S
After the motor has been installed and mounted, the brake (if available)
must be checked to ensure that it functions correctly!
Note
Flange mounting is only possible using studs and nuts. The clearance for
threading on nuts between the motor flange and motor enclosure in accor-
dance with DIN 42677.
Shaft height
100
132
160
180,
225
44 mm
50 mm
65 mm
m1
70 mm
90 mm
 Siemens AG 2000 All rights reserved