Download Print this page

Siemens SIMODRIVE 6SN11 Series Planning Manual page 209

Ac motors for feed and main spindle drives

Advertisement

09.00
Technical Data and Characteristics
3.1
Speed–torque diagrams
Note
For drive converter operation on 480 V line supplies, DC link voltages of
> 600 V are obtained. The following restrictions apply:
S
S
S
S
 Siemens AG 2000 All rights reserved
SIMODRIVE Planning Guide Motors (PJM) – 11.00 Edition
Motors, shaft heights 28, 36, 48, 63 and 80 may only be utilized acc. to
∆T = 60 K. Shaft heights 100 and 132 can still be utilized according to
∆T = 100 K.
The shift of the voltage limiting characteristics is described in Chapter
ALS/1.1.
The specified thermal S3 limit characteristics are referred to ∆T = 100 K.
The voltage limiting characteristic for DC link = 540V corresponds to the
limiting characteristic, previously shown in the Planning Guide (Edition
08.98). The new voltage limiting characteristic for DC link = 600 V can only
be used in conjunction with the drive function 'L(I) _:Adaption'. This is inte-
grated into the following systems:
SIMODRIVE 611 Digital from drive firmware 4.4.01
SIMODRIVE 611 Universal from drive firmware 3.2.2
6SN1197–0AA20
1FT6 AC Servomotors
3.1 Speed–torque diagrams
3
1FT6/3-25
1FT6

Advertisement