Download Print this page

Siemens SIMODRIVE 6SN11 Series Planning Manual page 436

Ac motors for feed and main spindle drives

Advertisement

1PH7 AC Main Spindle Motors
1.2 Cooling
1.2
Mounting
1PH7
1PH7/1-8
Cooling
Note
S
1PH7 main spindle motors are force–ventilated. When mounting the motor,
please ensure that the motor can be well ventilated. This is especially im-
portant for encapsulated designs. It is not permissible that the hot dischar-
ged air is drawn–in again.
S
Surface temperatures can exceed 100 °C .
The fan is mounted axially on the non–drive end.
The following min. clearance must be maintained to customer–specific mounted
components and the air discharge opening:
Table 1-5
Shaft height [mm]
100
132
160
180
225
The following minimum clearance S between the air intake and discharge ope-
nings and adjacent components must be observed:
Minimum clearance to air intake and air discharge openings
Fig. 1-1
Table 1-6
Shaft height 100
Shaft height 132
Shaft height 160
Shaft height 180
Shaft height 225
Min. clearance to customer–specific components
Min. clearance [mm]
30
60
80
100
100
Minimum clearance to air intake and discharge openings
Clearance S /mm
 Siemens AG 2000 All rights reserved
SIMODRIVE Planning Guide Motors (PJM) – 11.00 Edition
S
30
60
80
80
80
6SN1197–0AA20
09.00

Advertisement