Table 3-26
Standard motor 1FT5134. force–ventilated
Technical data
Engineering data
Rated speed
Rated torque
Rated current
Stall torque
Stall torque
Stall current
Stall current
Moment of inertia (with brake)
Moment of inertia (without brake)
Limit data
Max. speed
Max. torque
Peak current
Limiting torque
Physical constants
Torque constant
Voltage constant
Winding resistance
Three–phase inductance
Electrical time constant
Mechanical time constant
Thermal time constant
Weight with brake
Weight without brake
M [Nm]
360
320
280
240
200
160
120
80
40
0
0
Fig. 3-26
Speed–torque diagram 1FT5134. force–ventilated
1)
valid for a 600 V DC link voltage
 Siemens AG 2000 All rights reserved
SIMODRIVE Planning Guide Motors (PJM) – 11.00 Edition
1FT5134
Code
Units
n
RPM
rated
M
Nm
rated (100 K)
I
A
rated
M
Nm
0 (60 K)
M
Nm
0 (100 K)
I
A
0 (60 K)
I
)
A
0 (100 K
–4
2
J
10
kgm
mot
–4
2
J
10
kgm
mot
n
RPM
max
M
Nm
max
I
A
max
M
Nm
limit
k
Nm/A
T
k
V/1000 RPM
E
R
Ohm
ph.
L
mH
D
T
ms
el
T
ms
mech
T
min
th
m
kg
m
kg
A
C
1)
250
500
750
1000
1250
6SN1197–0AA20
1FT5 AC Servomotors
3.1 Speed–torque diagrams
–0SA71
–0SC71
1200
2000
115.0
110.0
46.0
74.0
90.0
90.0
120.0
120.0
34.0
56.0
45.0
75.0
665
665
590
590
1900
3200
300
300
134.0
222.0
164.0
156.0
2.70
1.61
306
182
0.19
0.073
4.8
1.8
25
25
3.2
3.2
85
85
107
107
100
100
1)
S1
1500
1750
2000
n [RPM]
1FT5
1FT5/3-53

Advertisement

loading