Download Print this page

Siemens SIMODRIVE 6SN11 Series Planning Manual page 197

Ac motors for feed and main spindle drives

Advertisement

09.00
Holding brake
Function description, refer to Chapter 2.2, General informationon AC
servomotors (AL S).
The holdinb brake cannot be retrofitted! Motors with holding brake are longer by
the space required to integrated the brake (refer to the dimension drawing).
Table 1-12
Technical data for the holding brakes used with 1FT6 motors used
Motor
Brake type
type
20 °C
1FT602V
EBD 0.11B
1.0
1FT603V
EBD 0.15B
2.5
1FT604V
EBD 0.4BA
6.5
1FT606V
EBD 1.5BN
19.0
1FT6081
EBD 1.2B
15.0
1FT6082
1FT6084
EBD 3.5BN
35.0
1FT6086
1FT610V
EBD 4B
100.0
1FT613V
EBD 8B
200.0
M
M
1)
standardized according to VDE 0580 with varistor circuit
2)
for each emergency stop with n=3000/min
3)
for each emergency stop with n=2000/min
W=1/2 *Jtot * ω
4)
2
Jtot [kgm
 Siemens AG 2000 All rights reserved
SIMODRIVE Planning Guide Motors (PJM) – 11.00 Edition
Holding
Dyn.
DC
torques
torque
cur-
1)
M
rent
4
[Nm]
[Nm]
[A]
120 °C
120 °C
1.2
0.75
0.3
2.0
1.6
0.4
5.0
3.5
0.8
22.0
10.0
0.7
12.0
8.0
0.8
28.0
17.0
0.9
80.0
43.0
1.4
140.0
60.0
1.7
= Average dynamic torque determined by the slip time t
1m
= Torque which can be transmitted, taking into account the max.
4
solenoid temperature, friction value flucturations and spread between
the units (production tolerances)
ω [ 1/s ]
;
2]
;
6SN1197–0AA20
1FT6 AC Servomotors
1.2 Functions and options
Power
Ope-
Closing
1)
drain
ning
time
time
[W]
[ms]
[ms]
7.5
20
10
9
30
15
18
30
15
17
130
20
21
70
35
23
180
35
32
180
20
40
260
70
W [ J ]
Mom. of
Highest
inertia
switch–
ing
[10
–4
work
]
2
2) 4)
kgm
[ ]
[ J ]
0.07
34
0.12
27
1.06
126
1FT6
3.2
321
3.2
740
13.5
1640
3)
32
2150
76.0
9870
3
1FT6/1-13

Advertisement

loading