D16 Camera Manual: Installation
Connection of additional
devices with more than
1 W (via MxBus/USB):
Max. ambient tempera-
ture +50 °C/+122 °F
40

2.3.2 Overview of Cable Connections

The following cables can be used with the D16:
MOBOTIX Ethernet cable : This MOBOTIX cable is pre-installed at delivery and is intended
for direct connection to a network outlet or PoE switch. If the D16 is to be installed
outdoors, the MOBOTIX MX-Overvoltage-Protection-Box should be used (optional
accessory).
MOBOTIX USB cable with MiniUSB connector : This MOBOTIX cable provides the
required impermeability, even in adverse weather conditions, and thereby prevents
corrosion of the connections.
Two-wire cables for MxBus modules : These cables can be used to connect MOBOTIX
modules. The wires of this cable are led along the bottom of the camera and then pushed
through the sealing membranes and into the cable guides.
MxBus
Only MOBOTIX cables should be used for the Ethernet and USB connection to ensure
that the cable cover remains permanently sealed.
Appliances with a maximum total power consumption of four watts may be connected
to the MxBus connector and USB connector if power is supplied to the camera using
PoE class 3 . If PoE Class 2 is used, the power consumption of all the connected
appliances must not exceed one Watt.
For information on changing the PoE class, see Section , «Variable PoE».