Overview Of Cable Connections - Mobotix D15D Manual

Table of Contents

Advertisement

54
/124
Connection of additional
devices with more than
1 W (via MxBus/USB):
Max. ambient tempera-
ture +50°C/+122°F
D15D Camera Manual: Mounting

2.3.2 Overview Of Cable Connections

The following cables can be used with the D15D:
• MOBOTIXEthernet cable : This MOBOTIX cable is pre-installed at deliv-
ery and is intended for direct connection to a network outlet. If the D15D
is to be installed outdoors, the MOBOTIX MX-Patch-Box should be used
(optional accessory).
• MOBOTIX USB cable with MiniUSB connector : This MOBOTIX cable
provides the required impermeability, even in adverse weather condi-
tions, and thereby prevents corrosion of the connections.
• Two-wire cables for MxBus modules : These cables can be used to connect
MOBOTIX modules. The wires of this cable are led along the bottom of the
camera and then pushed through the sealing membranes and into the
cable guides.
MxBus
Only MOBOTIX cables should be used for the Ethernet and USB connection to
ensure that the cable cover remains permanently sealed.
Appliances with a maximum total power consumption of four watts may be con-
nected to the MxBus connector and USB connector
camera using PoE class 3
the connected appliances should not exceed one watt.
For information on changing the PoE class, see Section 2.7.5, «Variable PoE» .
© MOBOTIX AG • Security-Vision-Systems • Made in Germany
MiniUSB
Caution
Ethernet
(network)
Caution
PoE Class 2
the power consumption of all
. If
is used,
www.mobotix.com • sales@mobotix.com