Nmark GCL Hardware Manual
2.2.2. Motor Supply Connections (TB201)
N O T E : This product requires two power supply connections. The Motor Supply and Control Supply
must both be connected for proper operation.
Motor power is applied to the Nmark GCL at the four terminals of the Motor Supply connector (TB201). The
DC+ and DC- inputs are internally fused.
W A R N I N G : Do not operate the Nmark GCL without the safety ground connection in place.
Table 2-4:
Motor Supply Input Wiring
Pin
Description
DC+
+40 VDC Input Range
RET
Return for DC Input
DC-
-40 VDC Input Range
Protective Ground (Required for Safety)
N O T E : Wire insulation rated for 300 V.
Table 2-5:
Motor Supply Mating Connector (TB201)
Type
4-Pin Terminal Block
www.aerotech.com
Figure 2-2:
Motor Bus Input Connections
Aerotech P/N
Phoenix P/N
ECK01581
1757035
Chapter 2
Installation and Configuration
Recommended Wire Size
2
2.1 mm
(#14 AWG)
2
2.1 mm
(#14 AWG)
2
2.1 mm
(#14 AWG)
2
2.1 mm
(#14 AWG)
Screw Torque
Wire Size:
Value: Nm
mm
0.5 - 0.6
3.3 - 0.0516 [12-30]
2
[AWG]
21