2.2. Power Connections

The Nmark GCL has two input power connectors; one for control power (AC) and a second for motor power
(DC). For a complete list of electrical specifications, refer to

2.2.1. Control Supply Connections (TB104)

N O T E : This product requires two power supply connections. The Motor Supply and Control Supply
must both be connected for proper operation.
The control power supply input supplies power to the Nmark GCL's communications and logic circuitry. Both
AC1 and AC2 inputs are fused internally.
The control power supply contains an internal filter and does not require an external filter for CE compliance.
Table 2-2:
Control Supply Input Wiring (TB104)
Pin
Description
AC1
Line Input: 85 - 240 Volt AC Input Range
AC2
Neutral (0V) or 85 - 240 Volt AC Input Range
Protective Ground (Required for Safety)
N O T E : Wire insulation rated for 300 V.
Table 2-3:
Control Supply Mating Connector (TB104)
Type
3-Pin Terminal Block
20
Figure 2-1:
Control Supply Connections
Aerotech P/N
Phoenix P/N
ECK00213
1754465
Chapter 2
Nmark GCL Hardware Manual
Section 1.1.
Recommended Wire Size
1.3 mm
1.3 mm
1.3 mm
Screw Torque
Value: Nm
0.5 - 0.6
www.aerotech.com
2
(#16 AWG)
2
(#16 AWG)
2
(#16 AWG)
Wire Size:
2
mm
[AWG ]
3.3 - 0.516 [12-30]