KANE 458s OVERVIEW

Your KANE458s combustion analyser measures:
● Carbon Monoxide (CO)
● Carbon Dioxide (CO₂)
● Oxygen (O2) if fitted
● Nitric Oxide (NO) if fitted
● Differential Pressure
● Differential temperature
Your KANE458s measures CO2 using KANE's unique NDIR sensor.
Always use fresh outdoor air to "zero" your analyser during the initial
countdown or when prompted to "ZERO CO" as indoor CO2 levels are
increased by human activity.
This applies even if your analyser measures O2 instead of CO2 as it is
best practice to use fresh, outdoor air during initial countdown to protect
you from unsafe levels of CO and CO2 possibly present in the room.
Depending on your options these parameters are calculated:
● Oxygen (O2)
● CO/CO₂ ratio
● Carbon Monoxide (CO₂)
● Combustion Efficiency
● Losses
● Excess Air
● Differential Temperature
Your analyser also measures CO levels in ambient air – useful when a
CO alarm is triggered – & performs a Room CO test for up to 30 minutes.
Your KANE458s has a structured Commissioning Test to help install boilers.
Your KANE458s has a protective rubber cover with magnets for
"hands-free" operation and is supplied with a flue probe with integral
temperature sensor.
Your analyser has a low flow detector to switch off the analyser's pump
if it detects an over filled water trap.