Functions
5.12 Safety functions
5.12.7

Settings of the SS1, SLS and SBC safety functions

Always parameterize the fail-safe functions using the STARTER PC tool. Parameterizing fail-
safe functions using the BOP is always very time consuming due to the fact that parameters
must be set twice.
The safety functions are parameterized according to the following schematic:
1. Go online with STARTER, open the screen with the safety functions and click on the
2. Enable the safety-related parameters by entering the correct password
3. Change the parameters of the safety function
4. Complete parameterization using the button
5. Confirm the checksums of the safety-related parameters
You will find a detailed description of the SS1, SLS and SBC functions in the Function
Manual: (http://support.automation.siemens.com/WW/view/en/31676845)
Safety function SS1 (Safe Stop 1)
Table 5- 91
Parameters
P9603 = ...
P9803 = ...
P9680 = ...
P9880 = ...
P9681 = ...
P9881 = ...
P9682 = ...
P9882 = ...
P9761 = ...
P9799 = ...
P9899 = ...
r9798 = ...
r9898 = ...
206
button
Safety-related parameters for SS1
Description
Selecting the signal source of the safety functions
Ramp deceleration
You will find a calculation formula for the ramp deceleration in the Function Manual
Ramp-down time of the braking ramp
Minimum frequency for the standstill detection
Password for the safety functions
Checksum of the safety-related parameters