Table 5- 45
Terminal No., significance
18
19
20
21
22
23
24
25
Further, the digital outputs can be interconnected with all binector outputs. A list of the
binector outputs is provided in the List Manual.
CU240S and CU240E Control Units, FW 3.2
Operating Instructions, 03/2009, A5E02440075B AA
Setting the functions of the digital outputs
NC
Digital output 0
NO
COM
NO
Digital output 1
COM
NC
Digital output 2
NO
COM
5.9 Evaluating the frequency inverter status
Parameter
Description
P0003 = 2
Extended parameter access
P0731
Possible values and functions for P0731, P0732
and P0732:
ValueFunction
0 Deactivate digital output
P0732
52.0 Drive ready
52.1 Drive ready for operation
52.2 Drive running
P0733
52.3 Drive fault active
52.4 OFF2 active
52.5 OFF3 active
52.6 Switching on inhibited
52.7 Drive alarm active
52.8 Setpoint/actual value deviation
52.9 PZD control
52.10 f_act >= P1082 (f_max)
52.11 Alarm: Motor current/torque limiting
52.12 Brake active
52.13 Motor overload
52.14 Motor CW rotation
52.15 Inverter overload
53.0 DC brake active
53.1 f_act < P2167 (f_off)
53.2f_act > P1080 (f_min)
53.3 Current actual value r0027 ≥ P2170
53.6 f_act ≥ setpoint (f_set)
P0748
Inverting digital outputs
Bit 0:Digital output 0
Bit 1:Digital output 1
Bit 2:Digital output 2
Functions