Dimensions, Hole Drilling Templates, Minimum Clearances, Tightening Torques - Siemens SINAMICS G120 Operating Instructions Manual

Hide thumbs Also See for SINAMICS G120:
Table of Contents

Advertisement

3.3.1

Dimensions, hole drilling templates, minimum clearances, tightening torques

Overview of dimensions and hole drilling templates for the Power Modules
0.37 kW ... 1.5 kW
Retaining type
2 x M4 bolts
2 x M4 nuts
2 x M4 washers
Tightening torques
2.5 Nm (22.1 lbf.in)
Distances from other devices
Lateral: 0 mm (0 inch) up to 40°C
30 mm (1.18 inch) from 40°C and
higher
Top/bottom: 100 mm (3.93 inch)
Depth
Standalone: 145 mm (5.71 inch)
With CU240E: 187 mm (7.36 inch)
With CU240S: 208 mm (8.19 inch)
CU240S and CU240E Control Units, FW 3.2
Operating Instructions, 03/2009, A5E02440075B AA
2,2 kW ... 4 kW
Retaining type
4 x M4 bolts
4 x M4 nuts
4 x M4 washers
Tightening torques
2.5 Nm (22.1 lbf.in)
Clearances to other devices
Lateral: 0 mm (0 inch) up to 40°C
40 mm (1.57 inch) from 40°C and
higher
Top/bottom: 100 mm (3.93 inch)
Depth
Standalone: 165 mm (6.50 inch)
With CU240E: 207 mm (8.15 inch)
With CU240S: 228 mm (8.98 inch)
3.3 Mounting Power Modules
7,5 kW ... 15 kW
Retaining type
4 x M5 bolts
4 x M5 nuts
4 x M5 washers
Tightening torques
2.5 Nm (22.1 lbf.in)
Clearances to other devices
Lateral: 0 mm (0 inch) up to 40°C
50 mm (1.96 inch) from 40°C and
higher
Top/bottom: 125 mm (4.92 inch)
Depth
Standalone: 185 mm (7.28 inch)
With CU240E: 227 mm (8.94 inch)
With CU240S: 248 mm (9.76 inch)
Connection