Parameter ID (PKE) and parameter index (IND)
The parameter ID (PKE) is always a 16 bit value. In conjunction with the index (IND), it
defines the parameter to be transferred.
PKE structure
● The parameter number is encoded in the lower 11 bits (PNU) of the PKE. Since the PNU
● Bit 11 (SPM) is reserved and is always 0.
● Bits 12 to 15 (AK) contain the request or response ID.
The meaning of the request ID for request telegrams (master → inverter) is explained in the
following table.
IND page index
Table 5- 69
Parameter range
0000 ... 1999
2000 ... 3999
4000 ... 5999
6000 ... 7999
8000 ... 9999
...
32.000 ... 33.999
...
64.000 ... 65.999
CU240S and CU240E Control Units, FW 3.2
Operating Instructions, 03/2009, A5E02440075B AA
can only contain values up to 2000, an offset must also be encoded for parameter
numbers above 2000. The offset is set in the first word of the index (IND) as shown in the
table below.
Regulations for setting the PNU
a
0
1
0
1
0
...
0
...
1
IND structure
Page index
b
c
d
f
0
0
0
0
0
0
0
0
0
0
1
0
0
0
1
0
0
1
0
0
...
...
...
...
0
0
0
1
...
...
...
...
1
1
1
0
5.11 Operation in fieldbus systems
Bit
Hex value
e
9
8
0
0
0
0x00
0
0
0
0x80
0
0
0
0x10
0
0
0
0x90
0
0
0
0x20
...
...
...
...
0
0
0
0x8
...
...
...
...
1
0
0
0xF4
Functions
+ PNU
0 – 7CF
0 – 7CF
0 – 7CF
0 – 7CF
0 – 7CF
...
0 – 7CF
...
0 – 7CF
155