Table 4- 9
Parameters
P0304 = ...
P0305 = ...
P0307 = ...
P0308 = ...
P0310 = ...
P0311 = ...
Table 4- 10
Parameter
P0700 = 2 or
6
P1000 = 2 or
6
CU240S and CU240E Control Units, FW 3.2
Operating Instructions, 03/2009, A5E02440075B AA
Motor data in accordance with the specifications on the motor rating plate
Description
Rated motor voltage (enter value as specified on the motor rating plate in Volt)
400 [v] (factory setting)
The rating plate data entered must correspond to the motor connection type
(star/delta) (i.e. with a delta motor connection, the delta rating plate data must be
entered).
Rated motor current (enter value as specified on the motor rating plate in Ampere)
1 [A] (factory setting)
Rated motor power (enter value as specified on the motor rating plate in kW or hp)
0.37 [kW / hp] (factory setting)
If P0100 = 0 or 2, the data is specified in kW
If P0100 = 1, the data is specified in hp.
Rated motor power factor [cos phi]
0.820 (factory setting)
This parameter is irrelevant when P0100 = 1 or 2.
Rated motor frequency (enter value as specified on the motor rating plate in Hz)
50.00 [Hz] (factory setting)
When this parameter is changed, the number of pole pairs for the motor is
automatically recalculated.
Rated motor speed (enter value as specified on the motor rating plate in rpm)
1395 [U / min]
Specify command source and frequency setpoint source
Description
Select the command source
0: Standard factory setting (restores the CU to the factory setting)
1: BOP (Basic Operator Panel keys)
2: Digital inputs (factory setting for 'stand-alone' CUs)
4: USS on RS 232
5: USS on RS 485
6: Fieldbus (factory setting for fieldbus-capable CUs)
Select the setpoint source
0: No main setpoint
1: MOP setpoint
2: Analog setpoint (factory setting for stand-alone CUs)
3: Fixed frequency
4: USS at RS 232
5: USS at RS 485
6: Fieldbus (factory setting for fieldbus-capable CUs)
7: Analog setpoint 2
4.6 Commissioning with the operator panel