Siemens SINAMICS G120 Operating Instructions Manual page 157

Hide thumbs Also See for SINAMICS G120:
Table of Contents

Advertisement

The meaning of the response ID for response telegrams (inverter → master) is explained in
the following table. The request ID determines which response IDs are possible.
Table 5- 72
Response ID
0
1
2
3
4
5
6
7
8
1) The required element of the parameter description is specified in IND (second word).
2) The required element of the indexed parameter is specified in IND (second word).
CU240S and CU240E Control Units, FW 3.2
Operating Instructions, 03/2009, A5E02440075B AA
Response ID (inverter → master)
Description
No response
Transfer parameter value (word)
Transfer parameter value (double word)
Transfer descriptive element
Transfer parameter value (field, word)
Transfer parameter value (field, double word)
Transfer number of field elements
Request cannot be processed, task cannot be executed (with fault number)
No master controller mode / no authorization to change parameters of the
PARAMETER CHANNEL interface
5.11 Operation in fieldbus systems
1)
2)
2)
Functions
157