3.2 Order code of Temposonics
1
2
3
4
5
R
H
a
b
a Sensor model
R
H Rod
b Design
B Base unit
D Threaded flange M18×1.5-6g (bushing on rod end)
H Threaded flange ¾"-16 UNF-3A (with fluoroelastomer housing-seal)
J Threaded flange M22×1.5-6g (rod Ø 12.7 mm, 800 bar)
M Threaded flange M18×1.5-6g (standard)
R Threaded flange M18×1.5-6g (thread M4 at rod end)
S Threaded flange ¾"-16 UNF-3A (standard)
T Threaded flange ¾"-16 UNF-3A (with raised-face)
U Threaded flange ¾"-16 UNF-3A (with raised-face &
fluoroelastomer housing-seal)
V Threaded flange M18×1.5-6g (with fluoroelastomer housing-seal)
c Stroke length
X
X
X
X M 0025...7620 mm
Standard stroke length (mm)*
25...500 mm
500...750 mm
750...1000 mm
1000...2500 mm
2500...5000 mm
5000...7620 mm
X
X
X
.
X
U 001.0...300.0 in.
Standard stroke length (in.)*
1...20 in.
20...30 in.
30...40 in.
40...100 in.
100...200 in.
200...300 in.
*/ Non standard stroke lengths are available; must be encoded in 5 mm / 0.1 in. increments
4/ Note: Specify magnet number for your sensing application and order separately
RH
®
6
7
8
9
10
11
D
5
6
c
d
Ordering steps
5 mm
10 mm
25 mm
50 mm
100 mm
250 mm
Ordering steps
0.2 in.
0.4 in.
1.0 in.
2.0 in.
4.0 in.
10.0 in.
12
13
14
15
16
17
1
U
3
0
1
e
f
d Connection type
6 2 × M12 female connectors (4 pin),
D
5
1 × M8 male connector (4 pin)
e Operating voltage
1 +24 VDC (−15 / +20 %)
f Output
1 Powerlink V2
U
3
0
Optional:
g Magnet number for multi-position measurement
Z
0
2 2 magnets
Z
0
3 3 magnets
Z
0
4 4 magnets
I 6 I
18
19
g
optional
4