Temposonics
R-Series Powerlink V2
®
Operation Manual
4.4 Styles and installation of Temposonics
Sensor electronics housing with bottom cable entry
41
(1.61)
49
(1.93)
Sensor electronics housing with side cable entry
41
(1.61)
49
(1.93)
Controlling design dimensions are in millimeters and measurements in ( ) are in inches
Fig. 12: Temposonics
RD4 sensor electronics housings
®
RD4
®
7.7
24.7
26.5
(0.3)
(0.97)
(1.04)
25
(0.98)
Ø 6.2
Ø 19
(Ø 0.24)
(Ø 0.75)
Mounting block
45
(1.77)
45
38
(1.77)
(1.5)
2
50
(0.08)
(1.97)
7.7
(0.39
24.7
(0.97)
8.2
(0.32)
Mounting block
5
(0.2)
Ø 18
(Ø 0.71)
45
(1.77)
38
(1.5)
45
(1.77)
Sensor electronics
housing
Sensor electronics housing
123
(4.84)
Recommendation:
Use M6×45 (ISO 4762)
screws for sensor fastening.
Fastening torque: 6 Nm.
24.7
(0.97)
Sensor electronics
housing
Ø 6.2
(Ø 0.24)
Sensor electronics housing
45
123
(4.84)
(1.77)
Recommendation:
Use M6×45 (ISO 4762)
screws for sensor fastening.
Fastening torque: 6 Nm.
I 14 I
18
(0.71)
18
(0.71)