MTS Sensors Temposonics E Series Operation Manual

MTS Sensors Temposonics E Series Operation Manual

Magnetostrictive linear position sensors, analog atex / iecex / cec / nec / ccc certified
Hide thumbs Also See for Temposonics E Series:

Advertisement

Temposonics
®
Magnetostrictive Linear Position Sensors
ET Analog ATEX / IECEx / CEC / NEC / CCC Certified
Operation Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Temposonics E Series and is the answer not in the manual?

Questions and answers

Summary of Contents for MTS Sensors Temposonics E Series

  • Page 1 Temposonics ® Magnetostrictive Linear Position Sensors ET Analog ATEX / IECEx / CEC / NEC / CCC Certified Operation Manual...
  • Page 2: Table Of Contents

    Temposonics ET Analog ATEX / IECEx / CEC / NEC / CCC Certified ® Operation Manual Table of contents 1. Introduction ..............................3 1.1 Purpose and use of this manual .................................. 3 1.2 Used symbols and warnings ..................................3 2. Safety instructions .............................3 2.1 Intended use ........................................
  • Page 3: Introduction

    Error in position measurement 1 to item 4 and only in conjunction with the third-party devices and are installed in a wrong order components recommended or approved by MTS Sensors. As a prereq- Wrong connection Signal output is disturbed –...
  • Page 4: Installation, Commissioning And Operation

    (VDE 0100, part 540; IEC 364-5-54). (ESD). 5. Sensors from MTS Sensors are approved only for the intended 11. Before applying power, ensure that nobody’s safety is jeopar- use in industrial environments (see chapter “2.1 Intended use”...
  • Page 5: Safety Instructions For Use In Explosion-Hazardous Areas

    For pigtail cables, place the cable ends in a static shielding bag for electrostatic discharge (ESD) protection. Fill the outer packaging around the sensor completely to prevent damage during transport. 2/ See also applicable MTS Sensors terms of sales and delivery on www.mtssensors.com...
  • Page 6: Identification

    Temposonics ET Analog ATEX / IECEx / CEC / NEC / CCC Certified ® Operation Manual 3. Identification 3.1 Order code Temposonics ® a Sensor model e Operating voltage T Rod/Profi le 1 +24 VDC (−15/+20 %) Version (see “Certifi cation of Temposonics ET (version A and b Design ®...
  • Page 7: Nameplate (Example)

    Principle of operation and system construction position measurement with both high accuracy and repeatability. The absolute, linear position sensors provided by MTS Sensors rely on the company’s proprietary Temposonics Modular mechanical and electronic construction magnetostrictive ®...
  • Page 8: Styles And Installation Of Temposonics ® Et (Rod Style)

    Temposonics ET Analog ATEX / IECEx / CEC / NEC / CCC Certified ® Operation Manual 4.2 Styles and installation of Temposonics ET (rod sensor) ® ET-F / -M / -S / -W, example: Version A / N Sensor electronics housing Null zone Stroke length...
  • Page 9 Temposonics ET Analog ATEX / IECEx / CEC / NEC / CCC Certified ® Operation Manual Hydraulics sealing There are two ways to seal the flange contact surface (Fig. 7): 1. A sealing by using an O-ring (e.g. 22.4 × 2.65 mm (0.88 × 0.1 in.), 25.07 ×...
  • Page 10: Styles And Installation Of Temposonics ® Et (Profile Style)

    Temposonics ET Analog ATEX / IECEx / CEC / NEC / CCC Certified ® Operation Manual 4.3 Styles and installation of Temposonics ET (profile sensor) ® ET-P, example: Version A / N Sensor electronics housing Null zone Stroke length Dead zone 50…3000 (~1.34) (2.17)
  • Page 11: Magnet Installation

    Temposonics ET Analog ATEX / IECEx / CEC / NEC / CCC Certified ® Operation Manual 4.4 Magnet installation Centered mounting of block magnet Typical use of magnets Air gap: 3 ±2 Magnet Typical sensors Benefi ts 8 ±2 (0.12 ±0.08) (0.31 ±0.08) Ring magnets Rod model...
  • Page 12: Electrical Connection

    Reference edge of mounting Do not underscore the minimum distance between the magnets of Start position End position 75 mm (3 in.) for multi-position measurement. Contact MTS Sensors 12 (0.47) 82 (3.23) if you need a magnet distance < 75 mm (3 in.).
  • Page 13 Temposonics ET Analog ATEX / IECEx / CEC / NEC / CCC Certified ® Operation Manual Grounding of rod sensors Connect the sensor electronics housing to machine ground. Ground sensor type ET version A (with ATEX/IECEx/CEC/NEC/CCC approval) via ground lug as shown in Fig. 19. Ground the sensor type ET version N (not approved) via ground lug as shown in Fig.
  • Page 14: Frequently Ordered Accessories For Et-F/-W/-M/-S

    Temposonics ET Analog ATEX / IECEx / CEC / NEC / CCC Certified ® Operation Manual 4.6 Frequently ordered accessories for ET-F/-W/-M/-S – Additional options available in our Accessories Guide 551 444 Position magnets Ø 32.8 (Ø 1.29) Ø 4.3 Ø...
  • Page 15: Frequently Ordered Accessories For Et-P

    Temposonics ET Analog ATEX / IECEx / CEC / NEC / CCC Certified ® Operation Manual 4.7 Frequently ordered accessories for ET-P – Additional options available in our Accessories Guide 551 444 Position magnets 15.2 57 (2.24) (1.65) (0.6) (1.69) (0.94) (1.69) (0.55)
  • Page 16: Frequently Ordered Accessories For Analog Output

    Temposonics ET Analog ATEX / IECEx / CEC / NEC / CCC Certified ® Operation Manual 4.8 Frequently ordered accessories for analog output – Additional options available in our Accessories Guide 551 444 Cables Tefl on cable Silicone cable ® Part no.
  • Page 17: Operation

    5.1 Getting started measurement tasks very easily via the connecting leads – without opening the sensor. Various MTS Sensors programming tools from the The sensor is factory-set to its order sizes and adjusted, i.e. the list of accessories (see page 14) are available for this purpose.
  • Page 18 Temposonics ET Analog ATEX / IECEx / CEC / NEC / CCC Certified ® Operation Manual 3. Set end position (100 % output) (Fig. 267): NOTICE • Set the position magnet on end position You can only adapt magnet 1 via hand programmer. In order to •...
  • Page 19: Analog Cabinet Programmer, Part No. 253 408

    Temposonics ET Analog ATEX / IECEx / CEC / NEC / CCC Certified ® Operation Manual 5.2.2 Analog cabinet programmer, part no. 253 408 Step 1: Install cabinet programmer Step 2: Connect cabinet programmer Install the built-in programming unit firmly in the control cabinet. It is Step 3: Adjust measuring range possible to change the start and end positions as well as the measur- ing direction via simple teach in process, see also “5.2.4 Setting ex-...
  • Page 20 Temposonics ET Analog ATEX / IECEx / CEC / NEC / CCC Certified ® Operation Manual 2. Set start position (0 % output) (Fig. 30): • Set the position magnet to start position • Press and release the “0 %” button Output 1 Output 2 Output from...
  • Page 21: Programming Kit, Part No. 254 555

    The PC programmer is a hardware converter between sensor and serial PC interface. It can be used for adjusting sensor parameters via computer and the MTS Sensors programming software, see also “5.2.4 Setting examples for programming tools” on page 23. The software...
  • Page 22 Temposonics ET Analog ATEX / IECEx / CEC / NEC / CCC Certified ® Operation Manual MTS ET Analog software user interface Fig. 34: Dialog field with tabs Fig. 33: MTS ET-Analog-Config V1.3, Function 1 In the File menu the sensor configuration can be saved on hard On tabs Function 2, Output 2, the second analog output can disk, printed out or loaded into the sensor .
  • Page 23: Setting Examples For Programming Tools

    Temposonics ET Analog ATEX / IECEx / CEC / NEC / CCC Certified ® Operation Manual 5.2.4 Setting examples for programming tools The sensor‘s measuring range can be repositioned within the active measuring range using the tools described above at any time. NOTICE Independent of the measuring direction, the location of the setpoints in the factory settings is always: SP1 (set point 1) at sensor...
  • Page 24: Maintenance And Troubleshooting

    Voltage output: 10.35 V Current output: 20.3 mA 6.3 Repair Adapted error value at output: −0.7…20.3 mA or −0.4…10.4 VDC Repairs on the sensor may be performed only by MTS Sensors or an (see on page 22) explicitly authorized body. Fig. 39: Troubleshooting 6.2 Maintenance...
  • Page 25: Technical Data Of Temposonics ® Et

    Temposonics ET Analog ATEX / IECEx / CEC / NEC / CCC Certified ® Operation Manual 8. Technical data of Temposonics ® Output Voltage 0…10 VDC and/or 10…0 VDC (minimum load controller: > 5 kΩ) Current 4(0)…20 mA and/or 20…4(0) mA (minimum / maximum load: 0/500 Ω) Measured value Position Measurement parameters...
  • Page 26 Temposonics ET Analog ATEX / IECEx / CEC / NEC / CCC Certified ® Operation Manual Certifi cation II 3G Ex nC IIC T4 Gc/Ex tD A21 IP66/IP68 T130°C II 3D Ex tc IIIC T130 °C Dc IP66/IP68 Class I/II/III Div 2 T4 ABCDFG Class I Zone 2 T4 IIC Zone 22 AEx tc T4 IIIC Dc −40 °C ≤...
  • Page 27: Appendix

    Please include safety data sheets of the substances, if applicable. Please include safety data sheets of the substances, if applicable. consult MTS Sensors to determine measures to be taken before consult MTS Sensors to determine measures to be taken before shipment.
  • Page 28: Declaration Of Conformity

    10. Declaration of conformity EU- Declaration of Conformity EU-Konformitätserklärung Déclaration UE de Conformité MTS Sensor Technologie GmbH & Co. KG www.mtssensors.com declares as manufacturer in sole responsibility that the position sensor type EC15.011D erklärt als Hersteller in alleiniger Verantwortung, dass der Positionssensor Typ déclare en qualité...
  • Page 29 EU Declaration of Conformity EU-Konformitätserklärung Déclaration UE de Conformité MTS Sensor Technologie GmbH & Co. KG www.mtssensors.com EC17.004C declares as manufacturer in sole responsibility that the position sensor type erklärt als Hersteller in alleiniger Verantwortung, dass der Positionssensor Typ déclare en qualité de fabricant sous sa seule responsabilité que les capteurs position de type Temposonics®...
  • Page 30 QPS Evaluation Services Inc Testing, Certification and Field Evaluation Body Accredited in Canada, the USA, and Internationally File LR1346 CERTIFICATE OF COMPLIANCE (ISO TYPE 3 CERTIFICATION SYSTEM) Issued to MTS Sensor Technologie GmbH & Co KG Address Auf Dem Schüffel 9, Lüdenscheid, Germany, D-58513 Project Number LR1346-3...
  • Page 31 QPS Evaluation Services Inc Testing, Certification and Field Evaluation Body Accredited in Canada, the USA, and Internationally File LR1346 Annex: Product: Linear Position Sensors Tempsonics ® E-Series ET Models: SSI Output, Analog & Digital Start/Stop Model (output) Canada Analog Ex nC IIC T4 Gc Class I/II/III Div 2 T4 ABCDFG Ex tc IIIC T130°C Dc IP66/68 Class I Zone 2 T4 IIC...
  • Page 33 MTS, Temposonics and Level Plus are registered trademarks of MTS Systems Corporation in the United States; MTS SENSORS and the MTS SENSORS logo are trademarks of MTS Systems Corporation within the United States. These trademarks may be protected in other countries. All other trademarks are the property of their respective owners. Copyright © 2021 MTS Systems Corporation. No license of any intellectual property rights is granted.