1 1.
Enor
Codes and Enor Messages
MELSEC GOT
11.2 Tab.bs of Error Codes and Error Messages
.
Error messages displayed before monitoring
I
Error message
Corrective action
Error contents
I
I
Check communication circuit.
(cable, driver, module)
Check for loose cables and mounting
Cable, installed communications driver, or
Also check the installed communica-
communications module is fautty
status of corf~fnuni~ations module.
tions driver.
~
Check memory data.
Arrangement of each installed
OS
program
sion.
version
is
improper.
Check each installed
OS
program ver-
Error code and error message dwing monitoring
Error codes and error messages detected by GOT are shown below.
The error code can be checked with the system information function of the error code
storage area and with the alarm list (system alarm) function.
For information on the system information function and the alarm list function, refer to the
SW2NIW-A8GOTP Operating Manual (Monitor Screen Creation Manual)
Errorcode
1
Error
message
Remedy
Error contents
I
Number of specified
I
monitoring points is ex-
cessive.
System work area cannot be secured be-
cause sprite settings of the screen to be
shown are excessive.
Reduce the number
of
sprite setting
sive.
points.
System work area cannot be secured be-
305
Number
Of
'pecified
cause sprite settings of the screen to be
printout
points
is
printed out by hard copy function are ex-
sive.
306
No monitor data
cessive.
Screen data is not downloaded to built-in
memory.
memory.
Download screen data to built-in
specfied basescreedwindow Screen
(1) Specify base screen/window
31
does not exist in project data.
Specified monitor data
does
not exist or is out-
1024)
is outside permissible range
(1 to
side range.
(2) Specify base screen/window
(2) Specified basescreedwindow screen
screen that exists.
screen of
1
to 1024 that exists.
Specified parts do not
exist or are outside
Check specified parts numbers
oi
Part No. set in parts display does not ex-
320
ist.
screen
data
parts
display.
32 1
ber of monitor device is
monitor does not
exist
or
is not an appli-
LnecK
incorrect.
Specified device is out-
cable monitor station.
Memory card capacity
CPU to be monitored.
applicable PC CPU.
ing range by setting parameter and PC
is outside the permissible range of the
Specifiez file register
is
Set device
in
the permissible monitor- The number
of the device to be monitored
OFF.
switch is OFF.
Memory card is not mounted or the Memory card is not
Check capacity. Memory card capacity
is insufficient.
tor In screen data.
322
331
is insufficient.
33'
outside range.
323
side ran e.
Format memory card. Memory card
is not formatted.
Format error
332
Mount memory card and'or turn
memory card access switch has turned mounted
or M-CARD
cess switch to ON.
11 - 2