Operation via the Emergency Open push-button

Resetting the Emergency Open push-button

In case of an emergency, the escape door can be released with the Emergency
Open module 1386D00. The release takes place immediately or after the lapse of a
configured release delay.
The Emergency Open push-button is locked in place after actuation.
1
Turn the red button of the Emergency open push-button to the right until the
button is released again.
9 Then the Emergency Open button is ready for operation again.
Note!
60 s wait time for reset to normal operation: If an alarm is acknowledged, e.g.
after an Emergency release, the acoustic alarm signal is suppressed immediately.
(Fig. 27)
The door terminal is reset to normal operation if
· a wait time of 60 s has passed,
· nor Emergency release commands are pending and/or
· all faults have been eliminated, e.g. the Emergency push-button has been
unlocked.