Key Switches; Down-Counter Module 1386D00-Coun; Interface For Locking Systems 1386S00 - Assa Abloy ePED 1386-00 Installation And Fitting Instructions

Escape route technology door terminal
Table of Contents

Advertisement

Key switches

With the key switch, the escape door is unlocked and operation is authorised.

Down-counter module 1386D00-COUN

The Down-counter module 1386D00-COUN displays the remaining wait time for a
delayed release of the locked escape door with green LEDs. Red LEDs also flash for
as long as the escape door is locked. Only the green lights illuminate continuously
if the escape door is released.
A
Attention!
Propy damage from connection with USB devices: The connection jacks on
the external display module 1386D00-DISP and on the Emergency Open module
1386D00 are not USB jacks and are only intended for connection of these two
devices via a standard USB cable A/B.
After connection, the external display module 1386D00-DISP shows the current
status of the system. Operation takes place interactively via touchscreen. If no
input takes place, the display switches back to status display after 15 seconds.

Interface for locking systems 1386S00

The Interface for locking systems 1386S00 is designed for connection of tested and
approved conventional escape route locking systems ("Test log for commission-
ing," page 60) to the Hi-O Technology™ bus with incorporation of safety-relevant
functions of ePED
®
(D01024xx ePED Interface for locking systems 1386S00 Manual).
EN