Unlocking or temporarily releasing an ePED

by Emergency Open push-button
Only possible in combination with the Central control unit 1386CMC.
Warning!
Life-threatening danger and risk of injury from locked escape route. If the
Emergency Open push-button is blocked, an alarm is triggered, but the ePED
1386-00 door terminal retains a Locked status.
®
rd
rd
rd
rd
rd
gn
ye
1:1
gn
gn
gn
gn
1386-00 door terminal blocked
The current status is:
· Emergency Open push-button
blocked
1
Turn the key switch to the
left:
With activation delay acti-
vated:
Hold the key longer than
the adjusted delay time.
9 The ePED
®
1386-00 door ter-
minal has an Unlocked sta-
tus.
®