Installation Instructions For ED5200N Series Exit Devices With 9600 TCRNE1 Series Trim M802 125 kHz Reader Option (Includes: Rim and SecureBolt™) FM294 10/18 Attention Installer Please read these instructions carefully to prevent missing important steps. Please Note: Improper installations may result in damage to the lock and void the factory warranty. Important: The accuracy of the door preparation is critical for proper functioning and security of this lock.
ED5000N (S)(A) Series Exit Device Table of Contents 1) Warning ................3 2) General Description .............4 3) Features ................4 4) Regulatory Specifications ...........4 5) Wiring Diagrams ..............5 6) Product Illustration .............7 7) Installation Instructions ............8 8) Surface Vertical Rod Installation Instructions ....14 9) Operational Check .............16 1) Warning Warning: Changes or modifications to this unit not expressly approved by the party...
ED5000N (S)(A) Series Exit Device 2) General Description The Corbin Russwin Access 600 TCRNE1 Series exit device is designed to interface with existing Wiegand Electrical Access Control (EAC) panels. The reader requires 12VDC for power and is available with 125 kHz HID proximity technology.
Page 6
ED5000N (S)(A) Series Exit Device 5) Wiring Diagrams (Continued) Typlcal ED5000N (S)(A) M802 Series Lock Application Diagram (24VDC Lock) MODE 1: LED WIRE NOT USED = RED LED ‘ON’ WHEN POWERED Standard Application Shown - For Alternative Applications Contact 1-800-810-WIRE (9473) Reader Electronics Require 12 or 24VDC UL294 Listed, Power Limited Power Supply (or UL603) *IMPORTANT: Pin 7 must be tied to earth ground in the access control panel.
ED5000N (S)(A) Series Exit Device 6) Product Illustration Item Part Number Description Req. 752F652 FIN Esc SA, M802 - Exits Rim/ CVR Functions (*9603, *9605) 752F662 FIN Esc SA, M802 - Exits SVR (LHR) Functions (*9S603, *9S605) 752F672 FIN Esc SA, M802 - Exits SVR (RHR) Functions (*9S603, *9S605) Exit Trim Refer to Access 600 Catalog to Configure Trim Order String Refer to Access 600 Catalog to Configure Rail Order String...
ED5000N (S)(A) Series Exit Device 7) Installation Instructions Inside Verify Hand and Bevel of door. Door should be fitted and hung. Verify box label for size of exit device, function and hand. Left Hand Right Hand Reverse Reverse Outside Fig. 1 Trim Assembly Instructions: Cylinder Collar Chart a.
Page 9
ED5000N (S)(A) Series Exit Device 7) Installation Instructions (Continued) Install Outside Trim a. Make sure tailpiece is oriented vertically. b. Feed trim wire harness through wire harness hole (Fig. 3a). c. Mount trim assembly to door pulling slack wire towards device side of door. Note: Be careful not to pinch wire harness.
Page 10
ED5000N (S)(A) Series Exit Device 7) Installation Instructions (Continued) Install Exit Device: a. Seat device against door being careful to align vertical trim tailpiece to engage with cross hole of device cam. b. Fasten device to trim assembly using (2) 1/4-20 pan head screws. c.
Page 11
ED5000N (S)(A) Series Exit Device 7) Installation Instructions (Continued) Install Head Cover: a. Lay wire harnesses (trim harness and device harness) across ¾” hole (Fig. 5a). b. Tuck wires into hole when installing cover so that wires are not pinched between head cover and door. c.
Page 12
ED5000N (S)(A) Series Exit Device 7) Installation Instructions (Continued) Install Outside Reader and Inside Mounting Plate. If this installation involves a surface vertical rod, go to the Surface Vertical Rod sectoin on page 12. a. Feed Reader wire harness through door and through hole in mounting plate (Fig. 6a). b.
Page 13
ED5000N (S)(A) Series Exit Device 7) Installation Instructions (Continued) Install Inside Escutcheon: Ground Wire a. Make electrical connections (Step 8). ElectroLynx Door b. Feed excess ElectroLynx® wire harness back into door. Harness c. Feed excess trim and exit device under head cover. d.
ED5000N (S)(A) Series Exit Device 8) Surface Vertical Rod Installation Instructions Install Inside Mounting Bracket with Outside Escutcheon. If this is a Surface Vertical Rod installation, follow the installation instructions on pages 4 - 8 before continuing: a. Position outside escutcheon against door (Fig. 4A). Note: Insert gasket, if necessary.
Page 15
ED5000N (S)(A) Series Exit Device 8) Surface Vertical Rod Installation Instructions (Continued) Attach Connectors (Interior PCB Assembly) a. Connect P5 (7-pin connector) from Reader board to J5 on interior PCB assembly (Fig 3a and 3b). From Reader b. Connect ElectroLynx harness (4 and 8-pin) from door Board P5 to J5 harness to ElectroLynx harness on interior PCB assembly (Fig 3a and 3b).
ED5000N (S)(A) Series Exit Device 8) Surface Vertical Rod Installation Instructions (Continued) Install Inside Escutcheon a. Position inside gasket and escutcheon against door. Verify that no wires are being pinched. b. Mount inside escutcheon assembly to plate using (2) #8-32 x 5/8" Phillips flat head undercut machine screws.
Page 17
Wiegand Test Unit 12 or 24VDC solenoid lock voltage adjustable The ASSA ABLOY Wiegand Test Unit verifies your installation in the field. The test unit checks for proper wiring, card reader data Operates as Fail Safe or integrity, lock functionality including lock/unlock, door position Fail Secure status, and request-to-exit (REX) status.