Tab. 5 :
Devices which have been tested in a device combination
All devices compatible at the time of the printing of this manual are listed.
Hi-O Technology™
device
Hi-O Emergency Open
push-button
External display module 1386D00 Disp
Key switch
Down-counter module 1386D00-Coun
Interface for locking
systems
Hi-O IO-interface for
top-hat rail
Panic push bar with
integrated emergency
switch function
EN
56
Type
Version
1386D00
1385ES2
1386S00
901-IO-20
N3140
N3640
Num-
Rated operat-
ber of
ing voltage in
nodes
accordance
with DIN EN
60950-1 SELV
2
12 / 24 V DC
0
from 1386D00
0
from 1386D00
1
12 / 24 V DC
1
12 / 24 VDC
Observe
operating volt-
age of the
locking element
2
12 / 24 VDC
2
12 / 24 VDC
Power input
12 V DC
24 V DC
200 mA
120 mA
170 mA
100 mA
is fed via the
Emergency Open
module
150 mA
80 mA
150 mA
100 mA
without locking
210 mA
110 mA
200 mA
120 mA
Set-up operation