Assa Abloy ePED 1386-00 Installation And Fitting Instructions page 45

Escape route technology door terminal
Table of Contents

Advertisement

I
Note!
The maximum number of components may not be exceeded: A maximum
of four terminals (Emergency Open module 1386D00) and eight Interfaces for
locking systems 1386S00 can be connected.
The maximum power consumption may not be exceeded: The voltage
supply must be sufficient for the power consumption of all connected
components.
Limitation of function with incorrect operating voltage at the compo-
nents. A mains adapter in accordance with DIN EN 60950-1 SELV must be
used. Separate mains adapters must be connected for the supply of devices
with power consumption higher than 100 VA. The appropriate mains
adapter, the cable lengths, and cable cross sections must be chosen accord-
ing to the local circumstances. Check and ensure that the operating voltage
at the connection points is suitable for the components.
Emergency Open
module 1386D00
Key switch
1385ES2
Fitting and installation
3
2
1
SYSCON 5
on
off
J1
1
2
3
4
5
6
7
8
J2
SYSCON 5
EN
45

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents