7.9.2 Ambient Temperature Range
-25 to 60 degrees C
7.9.3 Humidity Range
0 TO 90% R. H. Non-Condensing.
7.9.4 Altitude
Recommended up to 2000 meters
7.9.5 Housings
*General purpose panel mount weighing 7 lbs. and including hardware for 19" rack mounting.
*NEMA 4X wall mount in fiberglass enclosure weighing 54 lbs.
*Includes non-intrusive magnetic keypad.
7.9.6 Non-intrusive Magnetic Keypad
The ViewSmart 1600+ operator interface includes eight front panel touch keys
/
/
/
. A magnetic keypad offers these eight keys with adjacent magnetic keys. It is
useful in applications where it may be inconvenient to open the enclosure's door to access the touch
keypad.
7.9.7 Approvals
•
CE Mark
•
(Pending) C22.2 No. 142-M1987 - Process Control Equipment
•
(Pending) CAN/CSA-C22.2 No.152-M1984 - Combustible Gas Detection Instruments
•
(Pending) ANSI/ISA-12.13.01-2000 - Performance Requirements for Combustible Gas Detectors
•
(Pending) CSA-C22.2 No. 213-M1987
Division 2 Hazardous Locations
•
(Pending) UL Std No. 1604, Third Ed. - 1994 - Electrical Equipment for Use in Class I and II, Division
2; Class III Hazardous (Classified) Locations
•
(Pending) ANSI/ISA-12.12.01-2010 - Non-Incendive Electrical Equipment for Use in Class I and II,
Division 2 and Class III, Divisions 1 and 2 Hazardous (Classified) Locations
•
(Pending) CSA File # = 219995 and may be seen at: CSA-International.org.
UM-1097
Revision B
- Non-Incendive Electrical Equipment for Use in Class I,
Alarm
Menu
Next
Edit
Reset
/
/
/
/
88
Need help?
Do you have a question about the ViewSmart 1600+ and is the answer not in the manual?
Questions and answers