4.3.5.5
View Log File Trend
View Log File Trend displays historic 24 hours of data using the 24 Hour Trend screen format. The user
selects the date to be displayed and all active channels for that day are loaded into the ViewSmart 1600+.
Use the Up and Down buttons to scroll through the 16 channels of Historic data. The ViewSmart 1600+ 24
Hour Historic Trend data screen is identified by the cyan background color in the graph area. All alarm
processing is active during viewing of historic trend and if a new alarm becomes present a prompt will ask
the user if they would like to continue viewing the historic data or exit this mode and view real time
readings.
4.3.6 View Event Log
The ViewSmart 1600+ logs the last 2000 events, first in first out, in non-volatile memory so an SD card is
NOT necessary to view the event log. The events are time and date stamped and if channel specific the
number is shown in the right column. Use the Up and Down buttons to scroll through the events.
Logged Events include: Alarm 1 In, Alarm 1 Out, Alarm 2 In, Alarm 2 Out, Alarm 3 In, Alarm 3 Out, Fault In,
Fault Out, Comm Error, Config Error, IO Error, Cal In, Cal Out, System Boot, Cold Boot, Alarm Reset, Remote
Alarm Reset, Alarm Refresh, Marker, Configuration Change, and Event Log Cleared.
S y s t e m
V e r s i o n
C o n f i g u r e
Z o n e
N a me s
Mi mi c
Mo d e
S D
C a r d
V i e w
E v e n t
L o g
C l e a r
E v e n t
L o g
V i e w
S e n s o r
L i f e
4.3.7
Clear Event Log
After initial setup and testing of the controller, CLEAR EVENT LOG is used to manually clear all events
in the log file. If the event log is not cleared the older events will be pushed out as new ones occur.
UM-1097
Revision B
T i me
v 1. 0 0
0 9 : 4 2
0 9 : 3 0
~
0 9 : 2 8
~
0 8 : 15
~
2 1: 3 7
~
2 1: 3 5
~
2 1: 3 0
~
2 1: 2 8
~
17 : 5 6
15 : 5 3
11: 15
0 9 : 3 7
0 9 : 3 0
0 5 : 3 6
0 5 : 3 5
Figure 23 View Event Log System Menu
D a t e
E v e n t
0 7 / 13 / 2 0 10
A l a r m 1 o u t
0 7 / 13 / 2 0 10
A l a r m R e s e t
0 7 / 13 / 2 0 10
A l a r m 1 i n
0 7 / 13 / 2 0 10
S y s t e m B o o t
0 7 / 12 / 2 0 10
A l a r m 1 o u t
0 7 / 12 / 2 0 10
A l a r m 2
0 7 / 12 / 2 0 10
A l a r m 2
0 7 / 12 / 2 0 10
A l a r m 1 i n
0 7 / 0 9 / 2 0 10
C o mm E r r o r
0 7 / 0 2 / 2 0 10
C o n f i g
E r r o r
0 6 / 12 / 2 0 10
C o l d
B o o t
0 6 / 0 1/ 2 0 10
C a l
o u t
0 6 / 0 1/ 2 0 10
C a l
i n
0 5 / 2 4 / 2 0 10
F a u l t
o u t
0 5 / 2 4 / 2 0 10
F a u l t
i n
C h .
19
19
19
- -
0 7
o u t
0 7
i n
0 7
0 7
16
2 2
- -
4 6
4 6
3 2
3 2
30
Need help?
Do you have a question about the ViewSmart 1600+ and is the answer not in the manual?