Installation Guide for RFU-D-HP
5
Adaptor
1
DXDH-RM-MOUNT-ADPT-ff
Remote
Mount
Kit
6
Circ./Cir
1
Per Antenna Vendor. Not used for standard interface antennas (six feet and larger).
c.
Adaptor
Required Tools
•
Metric offset hexagon key set
•
Metric wrench key set
Common Installation
Prior to the installation, follow the antenna manufacturer's instructions for using the circular transition (adaptor).
Remove the existing rectangular transition, swap the O-ring, and install the circular transition instead.
Connect the OMT kit to the antenna and secure it with four screws.
Important Note!
Verify that the O-ring is properly mounted between the antenna transition and the OMT.
Page 71 of 179