Table of Contents

Advertisement

Installation Guide for RFU-D-HP
4
Roll back the foil shield insulation and wrap the drain wire around the foil. Do not remove any insulation
from the conductors.
5
Align the colored wires.
Note:
Cord colors should be matched to the same pins on both ends of the cable.
6
Trim all wires to the same length. About 12 mm on the left should be exposed from the inner sheath.
7
Separate the wires and place the twisted shield between the separated wires.
8
Insert the wires into the RJ45 plug. Verify that each wire is fully inserted into the front of the RJ45 plug
and in the correct order, according to the pinouts shown in Section Chapter 0, Outdoor CAT-5e Cable
Specifications. The sheath of the CAT-5e or CAT-6 cable should extend into the plug by about 13 mm and
held in place by the crimp.
9
Extend the cable jacket with the shield into the connector about 5 mm for strain relief and shielding
connection.
10 Wrap the twisted braid firmly around the cable jacket and let the crimping tail of the RJ45 plug envelop
it.
Important Note!
connected to the RJ45 plug.
To ensure proper grounding, it is essential that the twisted braid be firmly