Installation Guide for RFU-D-HP
4
Mount and tighten the O-ring and the Flexible WG to the RFU-D-HP MC Remote mount adapter ports
using the four screws supplied with the Flexible WG kit.
5
Mount and tighten the O-ring and flexible WG to both antenna ports using the four screws supplied with
the flexible WG kit.
The following example illustrates a typical configuration, assuming:
The regulation specifies a channelization of 8 consecutive 28/30 MHz channels (1-8ch).
The actual channels in use are channels 1, 5.
4+0 Configuration
Low Channels
Radio
(i.e: Ch1 V&H)
Antenna
High Channels
Ports
(i.e: Ch5 V&H)
1 2 3 4 5 6 7 8
8+0 Configuration
Page 126 of 179