Installation Guide for RFU-D-HP
Important Note! Before tightening the gland, make sure the gland is aligned with the tapped hole in
the unit. Tightening the gland at an angle can ruin the thread on the gland and prevent proper
sealing of the interface.
10 Insert the main part of the gland into the thread in the radio body and tighten until there is full contact
and the gasket is fully contained between the gland and the radio and cannot be seen. Tighten the gland
gently and make sure there is no resistance. If there is resistance, stop immediately, and thread out the
gland. Verify that the gland thread is not damaged and tighten the gland again.
Important Note! Pay attention that the gland rubber is properly located and not damaged during the
tightening of the gland cap.
If the gland thread is damaged do not use it!
11 Tighten the rear portion of the gland onto the main part of the gland and make sure that the main part
of the gland does not have an additional swivel after the rear portion is secured.
If the main portion of the gland is rotated while the rear portion is seizing the cable, this may ruin the
cable connector.