Dids; Serial; Power; Readbr - Broadcom NetXtreme BCM570 Series Diagnostic User Manual

Ethernet adapter
Table of Contents

Advertisement

Broadcom NetXtreme Ethernet Adapter • Diagnostic User's Guide
s ASPM L0s enabled
1 ASPM L1 enabled
a ASPM L0s and L1 enabled
Syntax: aspm [-e 0|s|1|a] [-r 0|s|1|a] [-x 0|1] [-d] [-i]
Options:
-r<string> Configure root complex device
-e<string> Configure endpoint (Broadcom) device (dut)
-x<DEC>
-d
-i
10.198

dids

cmd: dids
Description: The feature outputs the following information: PCI DID, VID, SDID &
SVID; MAC address, Firmware revision, PXE, PXESpd, WOL, ASF, MBA, Bond Rev.
This information can be used to verify the setup of a chip after a firmware upgrade.
Syntax: dids
10.199

serial

cmd: serial
Description: Compares the serial number to defaults or the provided values. This PCI
capability testing is only applicable to Shasta C stepping (i.e. BCM5752Cx) family.
Syntax: serial <dwordLo> <dwordHi>
10.200

power

cmd: power
Description: Verify the power function of PCI capability. This PCI capability testing is
only applicable to Shasta C stepping (i.e. BCM5752Cx) family.
Syntax: power
10.201

readbr

cmd: readbr
Enable ExtendedSync mode for root complex and endpoint (def=0)
Display present ASPM State
Ignore all previous ASPM setting after a chip reset
page 131