Operating the service processor

4.5.4 Setting up PROGRAM LOAD FRAME PRESET2

In the PROGRAM LOAD FRAME PRESET2 you specify which operating mode is to be set
after the server is switched on.
The following are specified in the example below:
VM2000 operating mode
Automatic startup of the operating system
Requirement
You are in the AUXILIARY FRAME: LOAD PRESET1.
Invoke the AUXILIARY FRAME: LOAD PRESET2 screen
Click on [PF9].
Ê
The AUXILIARY FRAME: LOAD PRESET2 screen is displayed:
-VM MODE-
==> 2
>1 NATIVE
*2 AVM/EX
-START IPL NO-
==> 1
>1 FIX(1)
*2 CURRENT
RA
Figure 30: AUXILIARY FRAME: LOAD PRESET2 screen
VM MODE ==>
START IPL NO ==>
U41859-J-Z126-2-76
----- AUXILIARY FRAME: LOAD PRESET2 -----
CL-0
CPU-0 CHP-0
Enter
for VM2000 operation
2
Always enter
Examples of SVP operation
E90L01G
*PF12
CATALOG
*PF9
GO TO LOAD PRESET-1
RUN
for automatic startup