Operating the service processor
4.4.8.4

(AU4) AUXILIARY FRAME: POWER STAND-BY/IMPL

RA
Figure 20: AUXILIARY FRAME: POWER STAND-BY/IMPL screen
By making an entry in this frame and pressing the [ENTER] key, you can switch the server
off or re-initialize it.
FUNCTION =>
1
2
U41859-J-Z126-2-76
----- AUXILIARY FRAME: POWER STAND-BY/IMPL ----- E90L01G
FUNCTION=>
*1 POWER STAND-BY
*2 IMPL
CL-0
The following function is selected after the corresponding number
has been entered:
POWER STAND-BY
IMPL
After you have selected a function and pressed the [ENTER] key, the following
prompt will appear:
***********************************
*
* ARE YOU SURE ? (ENTER Y OR N) N *
*
***********************************
v
CAUTION!
POWER STAND-BY or IMPL may not be executed during system
operation! If this instruction is not heeded, BS2000 will be aborted!
Press the [Y] and [ENTER] keys to switch off the system or to execute an IMPL,
Ê
or the [N] and [ENTER] keys to cancel the procedure.
CPU-0 CHP-0
RUN
switches the Server Unit off; order: first devices
connected to the PCI (Power Control Interface),
then the servers (for further information on this see
"Switching the SE700 / SE500 on and off" in the
Basic Operating Manual [1])
executes IMPL
*
*
SVP frames and subframes
[]-[]00