Mounting The Unit; System Cutout Dimensions - Xycom 9462 System Manual

Flat-panel
Table of Contents

Advertisement

9460/9460KP/9462/9462KP System Manual

Mounting the Unit

Once the conditions in the preceding sections have been met, follow the instructions be-
low to mount the unit:
1. Locate a position for your system that meets the specifications required (see previous
sections and Appendix A).
2. Cut the hole according to the cutout dimensions in figures Figure Chapter 3 -18 or
Figure Chapter 3 -19.
3. Make sure the area around the cutout is clean and free from metal burrs.
4. Install the unit.
5. Attach the power cable making sure that the system's enclosure is grounded through
the power cable.
6. Implement the proper grounding techniques. Establish a ground path from the unit
chassis to the enclosure chassis. A 6-32 threaded ground point hole is provided on
the bottom panel of the unit.
7. Tighten the 12-#10 nuts to 25 inch-lbs (2.8 Newton-meters) (28Kgf cm).

System Cutout Dimensions

9460/9462
3-28
Figure Chapter 3 -18. 9460/9462 System Cutout Dimensions