9462 Units; Mitsubishi Tft Flat-Panel Display (Model #Aa12Sb6C-Adfd - Xycom 9462 System Manual

Flat-panel
Table of Contents

Advertisement

9460/9460KP/9462/9462KP System Manual
11. Slide out the bulb assembly.
12. Slide the new assembly into the opening from which the old assembly was removed.
13. Repeat steps 10 through 12 to replace the bulb assembly on the right, outside edge of
the flat-panel display.
14. Reverse steps 1 through 8 to reassemble the unit.

9462 Units

Mitsubishi TFT Flat-Panel Display (Model #AA12SB6C-ADFD)

1. Turn off the power source.
2. Using a small Phillips-head screwdriver, loosen the two protruding captive screws at
the top back of the unit, and remove the lid.
3. If a touch screen is installed, disconnect the touch screen cable (TCH1) at the top of
the system board.
4. Set the unit with the front panel down and loosen the four captive screws holding the
front panel to the display adapter plate.
5. While securely holding the front panel, flip the unit over.
6. Lift off the front panel, and set it aside.
7. Unscrew the four screws that attach the flat-panel display to the standoffs.
8. Disconnect the bulb connector from the inverter card.
D-4
Xycom recommends replacing both bulbs at the same time.
Note