Xycom 3700 Series User Manual

Flat-panel industrial pcs
Table of Contents

Advertisement

Quick Links

Xycom 3700 Series User Manual

Advertisement

Table of Contents
loading

Summary of Contents for Xycom 3700 Series

  • Page 1 Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment SERVICE CENTER REPAIRS WE BUY USED EQUIPMENT • FAST SHIPPING AND DELIVERY Experienced engineers and technicians on staff Sell your excess, underutilized, and idle used equipment at our full-service, in-house repair center We also offer credit for buy-backs and trade-ins •...
  • Page 2 Flat-Panel Industrial PCs User Manual for the 3712KPM, 3712KPMT, 3715T, 3715KPM, & 3715KPMT Models © © © © 2007 XYCOM AUTOMATION, LLC. Printed in the United States of America Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 3 Trademark Information Xycom and Xycom Automation are trademarks of Xycom Automation, L.L.C. Xycom Automation, L.L.C. now is referred to as Pro-face through a D.B.A. The Pro-face name and logo will replace the Xycom name and logo on all documents where possible.
  • Page 4 Chapter Two - Testing EMC compliance is, in part, a function of PCB design. Third party add-on AT/XT peripheral PCB assemblies installed within this apparatus may void EMC compliance. FCC/CE compliant PCB assemblies should always be used where possible. Pro-face can accept no responsibility for the EMC performance of this apparatus after system integrator/user installation of PCB assemblies not manufactured and/or expressly tested and approved for compliance by Pro-face.
  • Page 5: Table Of Contents

    Table of Contents CHAPTER 1 – INTRODUCTION ..........................1 ..............................1 RODUCT VERVIEW ..............................1 TANDARD EATURES Front Panels.................................3 I/O Panel ................................7 Back Panel................................9 Power Panel...............................10 ............................11 NPACKING THE YSTEM ...............................11 UICK TARTUP CHAPTER 2 – INSTALLATION..........................12 ............................12 NSTALLATION VERVIEW ............................14 YSTEM UTOUT IMENSIONS 3712kpm(t).................................14 3715...
  • Page 6 3700 Series Flat Panel Industrial PC Table of Contents CHAPTER 4 – MAINTENANCE ..........................46 .........................46 ENERAL REVENTIVE AINTENANCE Fuse Replacement.............................46 Fan Filter Replacement............................47 .....................47 ECOMMENDED RIVE REVENTIVE AINTENANCE ..........................48 YSTEM ATTERY EPLACEMENT ............................51 RODUCT EPAIR ROGRAM 3700 F ............................53 RONT...
  • Page 7: Chapter 1 - Introduction

    Chapter 1 – Introduction Product Overview ® ® The 3700 series of Flat Panel Industrial Computers combines an Intel Celeron ® Pentium III processor with a flat-panel display to offer a powerful, compact package for the factory floor and other harsh environments. The PC features an open architecture to meet a wide variety of applications that require both a powerful PC and a durable industrial enclosure.
  • Page 8 3700 Series Flat Panel Industrial PC Chapter 1 – Introduction Standard Features of a 3700 Unit • • • • Flash BIOS • 6.42" mounting depth (maximum for all 3700 models) • Flat-panel active color TFT display: • – 12.1" (800x600) on 3712s –...
  • Page 9: Front Panels

    3700 Series Flat Panel Industrial PC Chapter 1 – Introduction Front Panels Figure 1-1 shows the 3715T front panel, and Table 2-1 outlines the features of this model. Figure 1-2 shows the 3712KPM(T) and 3715KPM(T) front panel, and Table 1-2 outlines the features of these models.
  • Page 10 3700 Series Flat Panel Industrial PC Chapter 1 – Introduction Table 1-1. 3715T Front Panel Features Feature Description Display The front panel has four components: a display; strengthened glass covering the display; a frame in which the display and the glass are mounted;...
  • Page 11 3700 Series Flat Panel Industrial PC Chapter 1 – Introduction 3712KPM(T) & 3715KPM(T) Front Panel Figure 1-2. 3715KPM(T) Front Panel The 3712KPM(T) and 3715KPM(T) feature function keys on either side of the flat panel display (PF1-PF20), function keys below the display (F1-F20), a numeric keypad, window keys, a cursor control keypad, diagnostic LEDs, an integrated mouse, industrial mouse/keyboard and USB ports.
  • Page 12 3700 Series Flat Panel Industrial PC Chapter 1 – Introduction Table 1-2. 3712/15KPM(T) Front Panel Features Feature Description Front Panel The front panel has four components: a display; strengthened glass covering the display; a frame in which the display and the glass are mounted; and the polyester overlay attached to both the glass and the frame.
  • Page 13: I/O Panel

    3700 Series Flat Panel Industrial PC Chapter 1 – Introduction I/O Panel Figure 1-3 shows the 3700 System I/O panel, and Table 1-3 outlines the features of the I/O panel. Figure 1-3. 3700 System I/O Panel 143311 (H) Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 14 3700 Series Flat Panel Industrial PC Chapter 1 – Introduction Table 1-3. 3700 System I/O Panel Feature Description Parallel Port The parallel printer port (LPT1) is a DB-25 female connector. This port provides a standard PC-compatible printer interface. COM Ports COM1 is RS-232/485 compatible.
  • Page 15: Back Panel

    3700 Series Flat Panel Industrial PC Chapter 1 – Introduction Back Panel Figure 1-4 shows the 3700 System back panel. Hard drive access CD-ROM drive Floppy drive Power connector and Figure 1-4. 3700 System Back Panel bracket 143311 (H) Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 16: Power Panel

    3700 Series Flat Panel Industrial PC Chapter 1 – Introduction Power Panel Figure 1-5 shows the 3700 System power panel, and Table 1-4 outlines the features of the power panel. Fan and filter Power connector Figure 1-5. 3700 Side Panel with Fan Filter and Power Connector Table 1-4.
  • Page 17: Unpacking The System

    3700 Series Flat Panel Industrial PC Chapter 1 – Introduction Unpacking the System When you remove the system from its shipping container, verify that you have the parts listed below. Save the box and inner wrapping in the event you need to reship the unit.
  • Page 18: Chapter 2 - Installation

    Chapter 2 – Installation This chapter offers detailed installation instructions and outlines the options for the 3700 series. It also includes the guidelines for preparing your 3700 unit for installation and use. Installation Overview Warning For installation in Hazardous Locations, review the Hazardous Locations Installation section in this chapter before startup.
  • Page 19 3700 Series Flat Panel Industrial PC Chapter 2 – Installation 5. Attach one end of the power cord to the power receptacle on the unit and the other end to a properly grounded 115/230 VAC, 50-60 Hz outlet. A ground path from the unit chassis to the enclosure chassis can be •...
  • Page 20: System Cutout Dimensions

    3700 Series Flat Panel Industrial PC Chapter 2 – Installation System Cutout Dimensions Figure 2-1 shows the system cutout dimensions for the 3712KPM(T). Figure 2-2 shows the system cutout dimensions for the 3715KPM(T). 3712kpm(t) 3712 Figure 2-1. System Cutout Dimensions (inches [mm]) 143311 (H) Artisan Technology Group - Quality Instrumentation ...
  • Page 21: 3715 Tkpmt & 3715 Kpm ( Tkpmt )

    3700 Series Flat Panel Industrial PC Chapter 2 – Installation 3715 & 3715 Figure 2-2. 3715 & 3715 System Cutout Dimensions (inches [mm]) 143311 (H) Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 22: Power Management

    3700 Series Flat Panel Industrial PC Chapter 2 – Installation Power Management The following paragraphs explain the system power, the power supply, and the effects of excessive heat, electrical noise, and line voltage variation of the 3700 unit. System Power Using isolation transformers on the incoming AC power line to the system is always a good practice.
  • Page 23: Excessive Heat

    3700 Series Flat Panel Industrial PC Chapter 2 – Installation Power Supply The power supply on 3700 models provides 200 Watts of output power throughout the system’s temperature range. The power available for expansion is limited, as shown in Table 2-1.
  • Page 24: Line Voltage Variation

    3700 Series Flat Panel Industrial PC Chapter 2 – Installation Line Voltage Variation The unit’s power supply is built to operate with input voltage ranges of 100 VAC and 240 VAC, while still allowing the system to function within its operating margin.
  • Page 25: Installing Internal Hardware Options

    3700 Series Flat Panel Industrial PC Chapter 2 – Installation Figure 2-4. Internal View of 3700 AC Power Connector 4. Insert the three wire ends of the power cable into the hole of the connector plug. Bend the Protective Earth ground (PE) wire, the neutral (N) wire, and the line (L) wire around the corresponding screws.
  • Page 26: Dram And Additional Dram Dual Inline Memory Modules (Dimms)

    The installation of any additional boards will void the UL Listing for Hazardous Locations compliance. Using a Touch Screen The 3700 series touch screen complies with environmental specifications and maintains a NEMA 4 seal when panel mounted. The touch screen controller emulates a Microsoft PS/2 mouse.
  • Page 27: Installing The Touch Screen Driver

    3700 Series Flat Panel Industrial PC Chapter 2 – Installation Installing the Touch Screen Driver In order to use the touch screen on your KPMT monitor, you must install the proper driver on the computer hooked to your monitor. For computers running Windows® 98, NT, 2000, or XP, you will be installing the driver touchbase_windows_kpmt_mons.exe.
  • Page 28: Calibrating The Touch Screen

    3700 Series Flat Panel Industrial PC Chapter 2 – Installation Calibrating the Touch Screen You need to calibrate the touch screen in the following cases: The cursor does not follow the movement of your finger or pen. • You adjust the size of the video image or change the video mode.
  • Page 29: Custom Logo

    You have the option to place a custom label on your unit. Refer to Figure 2-5 for the dimensions and recommended requirements for a customized label. Once a customized label is procured, place the new label over the “Pro-face /Xycom” label.
  • Page 30 3700 Series Flat Panel Industrial PC Chapter 2 – Installation 3712KPM(T) Keypad Inserts Figure 2-6 and Figure 2-7 show the keypad insert dimensions for the 3712KPM(T). Figure 2-6. 3712KPM(T) Keypad Inserts with Dimensions (PF1 – PF10) Note : The PF11-PF20 insert has the same dimensions 143311 (H) Artisan Technology Group - Quality Instrumentation ...
  • Page 31 3700 Series Flat Panel Industrial PC Chapter 2 – Installation Figure 2-7. 3712KPM(T) Keypad Insert with Dimensions (F1 - F20) 143311 (H) Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 32 3700 Series Flat Panel Industrial PC Chapter 2 – Installation 3715KPM(T) Keypad Inserts Figure 2-8 and Figure 2-9 show the keypad insert dimensions for the 3715KPM(T). Figure 2-8. 3715KPM(T) Keypad Inserts with Dimensions (PF1 – PF10) Note : The PF11-PF20 insert has the same dimensions 143311 (H) Artisan Technology Group - Quality Instrumentation ...
  • Page 33 3700 Series Flat Panel Industrial PC Chapter 2 – Installation Figure 2-9. 3715KPM(T) Keypad Insert with Dimensions (F1 - F20) 143311 (H) Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 34 3700 Series Flat Panel Industrial PC Chapter 2 – Installation Keypad Installation Diagram Figure 2-10. Keypad Insertion Diagram 143311 (H) Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 35: Hazardous Locations Installation

    Chapter 2 – Installation Hazardous Locations Installation Pro-face/Xycom designed the 3700 series to meet the requirements of Class I and II, Division 2 Hazardous Locations applications. Division 2 locations are those locations that are normally non-hazardous, but could become hazardous due to accidents that may expose the area to flammable vapors, gases or combustible dusts.
  • Page 36 3700 Series Flat Panel Industrial PC Chapter 2 – Installation Canadian Standard Association, Specification C22.2 No. 213-M1987. • • • • Non-incendiary electrical equipment for use in Class I, Division 2 Hazardous Locations (cUL Listed, File E180970) Canadian Standards Association, Specification C22.2 No. 142, (cUL •...
  • Page 37: Definitions

    3700 Series Flat Panel Industrial PC Chapter 2 – Installation Definitions The following Class and Division explanations are derived from Article 500 (Sections 5 and 6) of the United States National Fire Protection Agency National Electric Code (NFPA 70, 1990). The definitions are not complete and are included here only for a general description for those not familiar with generic Hazardous Locations' requirements.
  • Page 38: Groups

    3700 Series Flat Panel Industrial PC Chapter 2 – Installation Ignitable concentrations of Class I vapors or gasses are normally • • • • prevented by positive mechanical ventilation, but which may become hazardous due to mechanical failure of those ventilation systems.
  • Page 39: Power Switch

    Chapter 2 – Installation Power Switch The 3700 series does not have a power switch. The amount of input power required by this system classifies the power switch as an incendiary device because the voltage and current across the make/break device are capable of creating a spark.
  • Page 40: Hazardous Locations Control Drawing

    3700 Series Flat Panel Industrial PC Chapter 2 – Installation Hazardous Locations Control Drawing Warning The following control drawing applies to front panel ports only. Class I, Division 2, Groups A, B, C and D, and Class II, Division 2, Groups F and G...
  • Page 41: Operation And Maintenance

    Chapter 2 – Installation Operation and Maintenance The 3700 series systems have been designed for compliance with relevant spark ignition tests. However, please note that the workstation front panel contrast adjustment tactile switches and keyboard connector are the only make/break components intended to be exercised by the operator in the course of normal operation.
  • Page 42: Chapter 3 - Keypad Utility Program

    The keypad utility uses a menu bar and pull-down menu system. All menu bars are displayed across the top of the screen. “Pro-face/Xycom KP3 Utility” and the current menu titles are shown at the bottom of the screen (see Figure 3-1).
  • Page 43: Startup

    Open the def3612.pkm file in the main menu to program the keypad. (This file contains the default keypad settings for the 3700 series.) Changes to the default file should be saved to a new file with the pkm extension. If you do not open a file, the macros pull-down menu will not be available.
  • Page 44: Exit

    3700 Series Flat Panel Industrial PC Chapter 3 – Keypad Utility Program Exit Files Macros Upload Download Utilities Open Function Keys Factory Default KP Ctl Version Alpha Keys Close Exit Exit Save Save As Delete Exit <Company Name> KP3 Utility: MAIN L-Arrow, R-Arrow, Enter Figure 3-1.
  • Page 45: Macros Menu

    3700 Series Flat Panel Industrial PC Chapter 3 – Keypad Utility Program Macros Menu Note You must have a macro file in memory before the Macros Menu is available. To load a macro file, select the File/Open menu. When you select Macros, a keypad type pull-down menu is available. This pull- down menu provides the following choices: Function Keys, Alpha Keys, and Exit.
  • Page 46 3700 Series Flat Panel Industrial PC Chapter 3 – Keypad Utility Program Command Description Teach Allows you to record up to 105 keystrokes in a macro. When Teach is selected, a graphic representation of the keypad currently in memory displays. Menu bar choices are Exit, ASCII, and Click OFF.
  • Page 47: Upload Menu

    3700 Series Flat Panel Industrial PC Chapter 3 – Keypad Utility Program Command Description Edit/Paste Paste inserts a sequence of scan codes (which were saved in memory using Copy) into the macro. To paste a sequence of scan codes that were previously copied, position the cursor where you want the text to appear and then press 1.
  • Page 48: Utilities Menu

    3700 Series Flat Panel Industrial PC Chapter 3 – Keypad Utility Program Utilities Menu When the Utilities menu is selected, two choices are displayed: Factory Default, and Exit. Table 3-5 explains these choices. Table 3-5. Utilities Menu Command Description Factory Default Reprograms the keypad macros to the factory default settings.
  • Page 49: Keypad Scan Codes

    3700 Series Flat Panel Industrial PC Chapter 3 – Keypad Utility Program Note The download.dld file was created after the last keypad programming process. This includes both new programming and reprogramming the keypad to the factory default settings. Keypad Scan Codes The utility’s default keypad keycodes are listed in the following table.
  • Page 50 3700 Series Flat Panel Industrial PC Chapter 3 – Keypad Utility Program Table 3-6. Default Keypad Keycodes 3712KPM(T) F/A Key LED Off (Function Mode) F/A Key LED On (Alpha Mode) 3715KPM(T) Description Keyboard Make Break Codes Keyboard Make Break Codes...
  • Page 51 3700 Series Flat Panel Industrial PC Chapter 3 – Keypad Utility Program Table 3-6. Default Keypad Keycodes 3712KPM(T) F/A Key LED Off (Function Mode) F/A Key LED On (Alpha Mode) 3715KPM(T) Description Keyboard Make Break Codes Keyboard Make Break Codes...
  • Page 52: Chapter 4 - Maintenance

    Chapter 4 – Maintenance The 3700 series is designed to withstand the harsh environment of the factory floor. Routine maintenance can help keep your system in good operating condition. Preventive maintenance consists of several basic procedures that will greatly reduce the chance of system malfunction. Schedule preventive maintenance along with the regular equipment maintenance to minimize down time.
  • Page 53: Fan Filter Replacement

    3700 Series Flat Panel Industrial PC Chapter 4 – Maintenance Fan Filter Replacement To change the fan filter, remove the grill and filter as illustrated in Figure 4-1 and replace the filter. Then snap the assembly back into position. Figure 4-1. Fan Assembly Caution Do not operate the 3700 unit without a fan filter.
  • Page 54: System Battery Replacement

    If the AIM3 CPU board battery life is ended then the 3700 series computer will no longer maintain the configuration information, date, or time and the battery will need to be replaced.
  • Page 55 TO GAIN ACCESS TO THE BATTERY AND REPLACE: 1. Remove power from the 3700 series computer. If installed in a panel the computer must be removed and placed screen down on a bench. To work...
  • Page 56 3700 Series Flat Panel Industrial PC Chapter 4 – Maintenance 6. Remove the PCI backplane assembly by unscrewing the captive screw on the AIM3 CPU board and two screws on the left side of the rear chassis. The battery at AIM3 CPU board location ‘BATT1’ is now exposed next to the PCI backplane connector on the AIM3 CPU board.
  • Page 57: Product Repair Program

    6. Install the rear chassis top cover (five #6 screws on back). TO SETUP THE CMOS MEMORY: 1. Plug a QWERTY keyboard into the Keyboard port on the side of the 3700 series computer 2. Apply power to the 3700 series computer. The same ERROR and WARNING messages should appear as before battery replacement.
  • Page 58 3700 Series Flat Panel Industrial PC Chapter 4 – Maintenance Product model number, part number, quantity, serial number(s), and • warranty status Failure mode and failure systems • Purchase order number or repair order number • 3. Make sure the front panel assembly is properly attached to the unit.
  • Page 59: 3700 Front Panel Frame

    3700 Series Flat Panel Industrial PC Chapter 4 – Maintenance 3700 Front Panel Frame The 3712 and 3715 front panel frames are made of powder-coated aluminum. The key ingredients are pure polyester, TEPIC-G, titanium oxide, barium sulfate, leveling agent, and carbon black.
  • Page 60: Front Panel Overlay

    3700 Series Flat Panel Industrial PC Chapter 4 – Maintenance Front Panel Overlay The 3700 front panel polyester overlay may be adversely affected by combinations of chemical environments, temperature, and stress. For this reason, material that may come in contact with the 3700 unit should be carefully evaluated under end- use conditions for compatibility.
  • Page 61: Chapter 5 - Troubleshooting

    Chapter 5 – Troubleshooting Diagnostic Testing If you suspect that you are having hardware problems with your 3700 series, you can use the Pro-face diagnostic utility to check out the PC’s various ports and subsystems. The diagnostic utility is on the Documentation and Support Library CD included with your unit.
  • Page 62 3700 Series Flat Panel Industrial PC Chapter 5 – Troubleshooting Figure 5-1. Serial Loopback Connections 143311 (H) Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 63: Running The Tests

    3700 Series Flat Panel Industrial PC Chapter 5 – Troubleshooting Running the Tests To run the diagnostic tests, insert the DOS-bootable disk you created into drive A. Turn on the computer and the diagnostics program will boot-up. Figure 5-2 shows the Main Menu screen for the program.
  • Page 64: Reinstalling Operating Systems

    Chapter 5 – Troubleshooting Reinstalling Operating Systems The 3700 series CPU ships with MS-DOS® preinstalled. Windows® 98, Windows® 2000, Windows® NT, and Windows® XP Professional operating systems are also available. If you need to reinstall an operating system, refer to the appropriate section below.
  • Page 65: Windows ® 2000 Reinstallation

    2000). This document is devoted to the reinstallation of your Windows 2000 operating system and drivers, utilizing the Recovery Media provided with your Pro-face/Xycom industrial computer. If you want to install a new operating system or reinstall a current operating system, refer to the operating system’s manual for directions.
  • Page 66: Installing Drivers

    This procedure will destroy data that may exist on the hard disk drive. Installing Drivers This section describes how to install the video drivers, the video expansion capability, and the touch screen drivers associated with the 3700 series. Video Drivers Video drivers and the related expansion utilities are on the Documentation and Support Library CD that is included with the documentation kit.
  • Page 67: Touch Screen Drivers

    3700 Series Flat Panel Industrial PC Chapter 5 – Troubleshooting Expansion does not add any resolution to the existing information; it simply stretches the information to better fit the display. Text and graphic screens can look somewhat grainy from the process of expansion.
  • Page 68: Appendix A - Technical Specifications

    Appendix A – Technical Specifications Hardware Specifications Table A - 1 lists the hardware specifications for the 3712KPM(T), 3715T and 3715KPM(T). Table A - 1. Hardware Specifications Characteristic Hardware Specification 3712KPM(T) 3715T & 3715KPM(T) Mechanical Height Front Panel 12.22 in (310.38 mm) Front Panel 13.97 in (354.84 mm) Width...
  • Page 69: Environmental Specifications

    3700 Series Flat Panel Industrial PC Appendix A – Technical Specifications Characteristic Hardware Specification 3712KPM(T) 3715T & 3715KPM(T) 508 (Listed) 1604 (Listed) Agency CSA C22.2, No. 142 (Listed) Approvals CSA C22.2, No. 213 (Listed) Regulatory 47 CFR, Part 15, Class A...
  • Page 70: Appendix B - Block Diagram And Aim3 Layout

    Appendix B – Block Diagram and AIM3 Layout Figure B - 1 shows the diagram of the AC Block Model; Figure B - 2 shows the layout of the AIM3 CPU board. AC Model Block Diagram FLAT PANEL DC/AC INVERTER FLAT PANEL INTERFACE DIMM MEMORY CONN.
  • Page 71: Aim3 Cpu Board Layout

    Appendix C – Pinouts AIM3 CPU Board Layout Figure B - 2. AIM3 CPU Board Layout w/Jumper & Connector Locations 143311 (H) Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 72: Appendix C - Pinouts

    Appendix C – Pinouts This appendix provides the pinouts for the keyboard, mouse, LPT1, COM1, COM2, USB, and VGA connectors. NC indicates No Connection. Keyboard Port Connector The following table lists the signal definitions for the keyboard connector. It is a standard PS/2-compatible connector.
  • Page 73: Dual Usb Connector (Usb1)

    3700 Series Flat Panel Industrial PC Appendix C – Pinouts Dual USB Connector (USB1) The following table lists the signal definitions for the two USB connectors. Table C - 3. Dual USB Pinout Description Description 5VFUSE 5VFUSE USBP0– USBP1– USBP0+...
  • Page 74: Serial Port Connectors

    3700 Series Flat Panel Industrial PC Appendix C – Pinouts Serial Port Connectors Both RS-232 and RS-485 serial ports are supported. However, only one connector can be used at a time, as all termination is done outside the unit. Refer to the AIM3 manual for different RS-485 connectors.
  • Page 75: Com2

    3700 Series Flat Panel Industrial PC Appendix C – Pinouts COM2 The following table lists the signal definitions for the COM2 DB-25 connectors. Table C - 6. COM2 Connector Pinout RS-232 Signal Signal ORB_GND TXD2 RXD2 RTS2 CTS2 DSR2 DTR2...
  • Page 76: Appendix D - Aim3 Controller Jumpers

    APPENDIX D – AIM3 CONTROLLER JUMPERS Table D - 1 shows the position and function of the controller jumpers. Table D - 1. Controller Jumpers Jumper Position Function Not used – Not stuffed Provide ground return for +12V/+5V on COM2 connector 2-3 √...
  • Page 77: Appendix E - Tskam Settings

    APPENDIX E – TSKAM SETTINGS Table E - 1 shows the position and function of the switches on the TSKAM Board (Part Number 142430-001). Table E - 1. Jumper and Switch Settings for TSKAM Switches/Jumpers Position/Setting Function SW1 (1-4) Assembly Keypad type for 9915 SW1.1 ON, SW 1.2,3,4 OFF dependent Keypad type for 3700 All OFF...
  • Page 78: Appendix F - The Raid-Enabled Ipc Option

    When installed, the RAID controller bypasses the disk controller on the AIM3 board that runs the disk activity light. Therefore, the disk activity light on the 3700 Series units will not function for the HDDs once the RAID controller is installed. However, the disk activity light will function for the CD-ROM, CompactFlash or any X-Bay units, as the RAID controller does not bypass these items.
  • Page 79 controller detects any problems with the primary drive, it switches over to the secondary drive (which has an exact copy of all data on the primary drive) and informs the operator of the switchover. If the RAID controller should detect any problems with the secondary drive, it stops writing to it and informs the operator of the problem.
  • Page 80 Index Access Drives floppy disk drive ..........10 floppy disk ............10 keyboard port ............6 Dual Inline Memory Modules........20 AIM3 Enclosures ............. 32 jumpers .............. 70 Fan..............10, 46 Battery..............48 filter replacement ..........47 Bottom panel............10 Features Cable standard ...............
  • Page 81 Parallel port connector ........... 67 Preparing the system ..........12 PC/AT installation and PCI boards ......20 Preventive maintenance ........46 Pinouts battery ..............48 COM1..............68 general ............... 46 COM2..............69 hard drive ............47 keyboard connector ........... 66 Printer port ...............
  • Page 82 143311 (H) Xycom Automation, LLC. Canada Sales: 905-607-3400 750 North Maple Rd. Northern Europe Sales: +44-1604-790-767 Saline, MI 48176 Southern Europe Sales: +39-011-770-53-11 Phone: 734-429-4971 Fax: 734-429-1010 http://www.profaceamerica.com Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 83 Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment SERVICE CENTER REPAIRS WE BUY USED EQUIPMENT • FAST SHIPPING AND DELIVERY Experienced engineers and technicians on staff Sell your excess, underutilized, and idle used equipment at our full-service, in-house repair center We also offer credit for buy-backs and trade-ins •...

This manual is also suitable for:

3712kpm3715kpmt3712kpmt3715t3715kpm

Table of Contents