2Nd Level Programming - BFT CDS 1.3 Installation And Operation Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 21

·
: Close confi guration
:
-
Close-when-released input
This mode has been developed so the bollard closes automatically only when the vehicle has completely passed by the photocell
or magnetic detector (the most suitable accessories for this purpose). Connect the N.O. contact of the detector or photocell to the
Close contact terminals.
If the vehicle is on the detector or in front of the photocell it does not cause immediate closing but rather you have to wait for the
signal to be released.

-
: The close command acts as a release closing and safety function.
When closing, the close command engaging stops the automation. When disengaged the bollard resumes closing.

·
: Default
- To reset the default parameters, set parameter  on 1 and exit the menu' .
- To restore the default parameters and confi gure the parameters for installation type A, B, C and D, set the corresponding default
and quit the menu. See chapter 12 for details on installation type.

·
: Automation statuses display
- During operation, the control unit displays automation status so the installer is able to follow the logical fl ow of the board.
The statuses are:
: Idle
: Opening

: Stop opening limit switch
: Stop opening
: Closing

: Stop closing limit switch
: Stop closing
The following table gives the 2nd level functions and the single settable parameters.
= DEFAULT value set in factory.
Par
Function

Request for maintenance
Programming maintenance

cycles in thousands
Programming maintenance

cycles in millions

AUX output

TERMON
Deceleration rotation torque

(not available for
GRIZZLY / OAK 800)

Exiting the menu/saving
Control unit
7.3
PROGRAMMING
2nd LEVEL
= parameter value set during installation: must be indicated if
: disabled
: active on the confi gured outputs
: active on the confi gured outputs and the bollard lights fl ash twice

..
: scheduled maintenance required
: photocell triggering
: obstacle detection (for GRIZZLY / OAK 800.4 only)
: PDM contact actuated
: bollard up
: bollard retracted
: stop contact actuated
: warning fl ash
: start contact
: open contact
: blackout (the contact is activated when turned on)
: assistance required
: motor temperature increase in °C

Exit programming and view machine Statuses (see notes  automation Statu-
ses display after the 1st level table)
- 27 -
: Stop due to photocell triggering

: Opening due to photocell triggering
: Photocell triggering pause
: Stop due to a detected obstacle

: Opening due to a detected obstacle
: Obstacle detection pause
: Maximum working time in opening reached

: Maximum working time in closing reached
DEFAULT value is modifi ed.
Settable data
EN


.




Advertisement

Table of Contents
loading

Table of Contents