Installation D Controlled Entry And Automatic Exit - BFT CDS 1.3 Installation And Operation Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 21
12.4
This solution is recommended when you want to enter a reserved area in both directions. To enter, transit is allowed by means of a recognition
command while exiting is automatic.
ENTRY
The vehicle approaches
the reserved area.
EXIT
Loops S1 and S2 also have a safety function in that they will not let the device move all the time the vehicle is on top.
DIMENSIONS
- Connect the contact of the coil S1 receiver to input PDM.
- Connect the N.O. contact of the S2 loop receiver to input OPEN.
- The dimensional values of the loops are only approximate.
*
We suggest installing the "MAK-2" metal mass detector.
Control unit
INSTALLATION D
CONTROLLED ENTRY AND AUTOMATIC EXIT
PARAMETER
DATA






- 35 -
When the vehicle is on loop S1 the
device will move down only after a
recognition command.
If the device is moving back up and
you want to lower it again the vehicle
must be on loop S1 and then you must
activate the recognition command.
When the vehicle is no longer on
loop S2 the device will move back
up automatically after an adjustable
pause time.
The vehicle approaches the reserved
area.
Occupying the coil S2 activates bol-
lard descent.
When the vehicle is no
longer on loop S1 the
device will move back
up automatically after an
adjustable pause time.
DESCRIPTION
Functioning logic: Automatic
Special function
Radio channel 1: Open
EN