5. PRELIMINARY OPERATION
- Before sending a command to the automation, make sure to have selected correctly the type of bollard as follows:
Bollard selection
- Hold down buttons F and + for 2 seconds to select the connected bollard.
- Select the type of bollard using the buttons +/-.
- Press F and + to confi rm.
GRIZZLY Ø273-600
GRIZZLY Ø273-800 / OAK 800.4
GRIZZLY Ø273-600/SCT
GRIZZLY Ø273-800/SCT / OAK 800.4/SCT
DKN Ø220-500
DKN Ø220-700
- Select network frequency through Ht parameter. (see 3rd level programming).
- (GRIZZLY / OAK 800.4 only) Select the pressure switch type with the parameter (see 3rd level programming).
- Check the connection method for simultaneous operation, if controlling multiple deterrent devices simultaneously (see paragraph 9).
6. INPUT AND OUTPUT FUNCTIONALITY AND CONNECTIONS
LINE
230V 50/60Hz power supply with mov internal protection and 8A T fuse (5x20).
Connect the phase and neutral as shown on the screen printing. Use a cable type H07RN-F 2x1.5+E min.
Connect the yellow/green wire of the power supply mains to the earth terminal of the appliance.
L N E
OUT24
Output 24Vac, 1A MAX
24 Vac
LED (Cover lights)
Self-powered output. 24Vac, 100mA max
BZ (Cover buzzer)
Self-powered output. 24Vac, 100mA max
AUX
Programmable volt-free relay output, max. 500mA, 24Vac/dc. Use parameter -lev. 2 for confi guration.
2nd
2nd CH RX
CH
RX
Free contact relay output; 500mA max, 24Vac/dc
Control unit
BOLLARD TABLE
6.1
POWER TERMINAL BLOCK
230V
6.2
POWER TERMINAL BLOCK
MOTA
MOTA/APERTURA
COM
M
COM
MOTB
MOTB/CHIUSURA
CAP
CAP
CAP
CAP
EV
EV
EV
EV
SL
SL (Flashing light)
SL COM
GR
GR (green light)
RD
RD (red light)
6.3
OUTPUTS/ACCESSORIES TERMINAL BLOCK
EASY Ø115-500
EASY Ø200-700
DEFENDER Ø273-700
DEFENDER Ø273-700A
DK/E-V
DK/E-S
Motor capacitor
(Supplied with bollard)
Electrovalve (230Vac) only GRIZZLY / OAK 800.4
Flashing light (230Vac)
Traffi c light (230Vac)
- 23 -
EN
DK Ø210-500
DK Ø210-700
DK/500V
DK/700V