2Nd Level Programming - BFT PERSEO CBE 230.P SD Installation And User Manual

Table of Contents

Advertisement

• [ L: Close configuration
D
-
I: Close-when-released input
The bollard closes automatically only when the vehicle has completely passed by the photocell or magnetic detector (the recom­
mended accessories for this purpose). Connect the N.O. contact of the detector or photocell to the close input terminals.
If the vehicle is on the detector or in front of the photocell it does not cause immediate closing but the control board will wait for
the signal to be released (i.e. vehicle moved).
- 02: The close command acts as close-when-released and safety function.
When closing, a close command stops the automation. When close input becomes inactive the bollard resumes closing.
-Pr : Preset
- To configure the parameters for installation type
details on installation types.
dF:
Default
- To restore the parameters to the factory default values, set the "DF" to 1 or 2, then exit the menu. if PF=
"Com" settings is are kept.
Warning:The"default" operation sets all parameters to the factory default values, including the Preset values and the bollard type.
The following table gives the 2nd level functions and the adjustable parameters.
� - DEFAULT
-
Par
Function
Sr
Request for maintenance
Programming maintenance cycles
nt
in thousands
Programming maintenance
nl
cycles in millions
oY
Output 4, Output 5
oS
F[
Closing limit switch presence
ECD present (for SD version and 00: not present
EF
XPASS B 1200C)
tE
TERMON
www.BFTGateOpeners.com | (800) 878-7829 | Sales@BFTGateOpeners.com
8.3
2nd LEVEL
va ue se in ac ory.
I
t • f t
00: disabled
0 I: active on the configured outputs
02: as in O I plus lights flash twice
00-99
0.0-9.9
00: scheduled maintenance required
0 I: photocell triggering
02: obstacle detection (for hydraulic bollard only)
03: PDM input active
OY: bollard fully up (close position)
05: bollard fully down (open position)
06: STOP input active
01: warning flash
OB: START input active
09: OPEN input active
10: power failure (the output is activated at switch-on)
I I: assistance required
12: CLOSE input active
13: UPS
IY: second radio channel active
15: buzzer (for Totem)
16: ECD pressure switch failure
11: FCC sensor failure or manual forcing attempt
0: not present
0 I: present
0 I: present
00-30: heating level (0 I= min; 30 = max)
Control unit
C and
set the corresponding value and exit the menu. See chapter 13 for
A, B,
D;
PROGRAMMING
= parameter value set during installation: should be filled if DE-
,.e.
..._
IA\ FAULT value is modified.
Settable data
- 31-
m
2 the communication
ti\
00
00
0.0
I I
0
I I
0
see
note
00
00