N.O. input that operates the bollard's opening and closing. The command is ignored while opening.
PDM
Input programmable with -level 3, -level 3 and -level 2 parameters. May be duplicated in AUX output.
OPEN
N.O. input - opening only.
By keeping this input controlled, the automation performs the opening manoeuvre and will close automatically only when the
input is freed. Connect clocks, daily timers or weekly timers here if wanted.
CLOSE
N.O. input for closing. It allows the automation to be closed only if the safety devices have not triggered. Operating mode
programmable with parameter -level 1.
FTC
N.C. safety input (photocell). Enter the programme wanted by programming the -level 1 parameter. It triggers only in the
closing phase; it never triggers in opening.
STOP
N.C. safety input. When it is activated, the automation is immediately stopped. During the pause time, a stop control eliminates
the automatic closing, leaving the bollard open waiting for a command.
FCA
Limit switch N.O. input in opening. When activated the opening travel fi nishes.
FCC
Closure travel limit pressure switch input (see paragraph 7.4, parameter PP). Limit switch N.C. input in closing.
When activated the closing travel fi nishes (For GRIZZLY / OAK 800.4 only).
EF
BT Input for anti blackout electric brake feeder (not available for GRIZZLY / OAK 800.4)
+
BAT
Permits the continuous power supply of the electric brake even without electrical energy, preventing the bollard from
lowering spontaneously in case of a blackout. Do not connect the batteries directly to this input but request the original
SHIELD
accessory "BATT-US".
ANT
ANTENNA
Antenna connection for the integrated receiver.
6.4
INPUTS/OUTPUT TERMINAL BLOCK
J10
6.5
ELECTRIC BRAKE TERMINAL BOARD/ANTENNA
EF Electric brake output (not available for GRIZZLY / OAK 800.4)
Connection for two white power supply cables for the motor's parking electric brake.
Activation is possible only when the bollard is completely lifted (24Vcc / 12Vcc).
J13
6.6
PROGRAMMER CONNECTOR