3. TECHNICAL SPECIFICATIONS

- Power supply:
- Motor output:
- Flashing light/traffi c light:
- Accessory output:
H
P

4. INSTALLATION SAFETY

In order to reach the level of safety required by current regulations, read the following prescriptions carefully.
1) Make all the connections in the terminal block after carefully reading the instructions given in this manual and observing the general
rules and technical standards governing electrical systems.
2) Upstream from the installation, fi t an omnipole miniature circuit breaker with a contact gap of at least 3 mm.
3) If there isn't one already, install a residual current device with a threshold of 30 mA.
4) Check the eff ectiveness of the grounding system and connect to it all the parts of the automation fi tted with a terminal or grounding
cable.
5) Fit at least one external warning device, such as a traffi c light or fl ashing light, along with a warning or danger sign.
6) Fit all the safety devices required by the type of installation, taking into consideration the risks it can cause.
7) Separate the power lines (min. sect. 1.5 mm
Control unit
230Vac +-10%, 50/60Hz
230Vac; 3A max
230Vac; 40W
24Vac; 1A max

3.1 CONTROL PANEL DIMENSIONS

L
2
) from the low-voltage signal lines (min. sect. 0,5 mm
L
=
200,05 mm
H
=
275,50 mm
P
=
126,08 mm
- 22 -
2
) in the ducts.